Loading...
Item 5 - Award of Contract; Sound Image for Mickey Cafagna Audio Video System RFP 21-007October 20, 2020, Item #5DATE: TO: FROM: CONTACT: SUBJECT: Summary: AG EN DA REPORT City of Poway October 20, 2020 Honorable Mayor and Members of the City Council Aaron Beanan, Director of Finance M:> Brad Rosen, Assistant Director of Finance Operations ~ (858) 668-4452 or brosen@poway.org CITY COUNCIL Award of Contract to Sound Image for the Mickey Cafagna Community Center Audio/Video System, RFP No. 21-007 The City is currently in the construction phase of the Mickey Cafagna Community Center that will provide outdoor spaces, multipurpose and dance studio spaces and an auditorium for a variety of community uses. The new facility requires a cost-effective, flexible-use, industry-standard Audio/Video (AV) system from a qualified AV Contractor to provide expertise in system design, installation and integration. The City issued RFP 21-007 for these services and is recommending selection of Sound Image to provide Audio Video Component and Installation Services. Recommended Action: It is recommended that the City Council award the contract for the Mickey Cafagna Community Center AV System, RFP No. 21-007 to Sound Image, the most qualified bidder, in the amount of $168,773.00. Discussion: The AV system for the new facility is designed to meet the variety of potential uses of the Community Center. In order to meet the variety of needs for the auditorium and multipurpose rooms, the design incorporates projectors for video presentation, wireless microphones and speakers that provide the functionality needed for meetings and background music. For the dance studio, the system design provides the ability for an instructor to playback audio wirelessly or through a cable. A Request for Proposals (RFP) for AV system design and installation was issued on August 6, 2020. The City posted the RFP on Ebidboard and advertised it in newspaper on August 6 and August 13, 2020. The City received proposals from eleven vendors and staff reviewed and evaluated the proposals based on the following criteria: 1) Experience of the vendor; 2) Professional, technical and educational qualifications of the personnel; 3) Quality of the solution proposed; and 4) Total cost. The services offered by the vendors were compared to identify where each met the requirements of the RFP and four vendors who offered prices in the lower half of the spectrum were shortlisted to 1 of 49 October 20, 2020, Item #5move on for additional evaluation. One of the more important factors in the evaluation was the vendors experience designing, configuring and implementing the Q-SYS system. The Q-SYS system is the underlying hardware platform that provides the AV functionality needed to meet the variety of needs of the Community Center. This system includes the control system, audio engine, touch panels and other required equipment. Adjustments to quoted quantities and options in vendor proposals were made to best compare total cost. The table below represents the comparative costs based on like services provided by the vendors. EKC Enterprises No $145,000.00 TekWorks Yes $1 53,400.37 AVI-SPL Yes $157,415.86 EIDIM Yes $168,318.07 Sound Image Yes $168,773.00 AVI Yes $176,462.10 Digital Networks Group, Inc. Yes $177,861.45 ExhibitOneAV Yes $179,958.00 Western Audio Visual & Security Yes $187,331.22 AudioAssociates Yes $208,234.97 Audio Visual Design Group Yes $224,486.67 Vendor selection for this type of service is made by a qualification-based selection. After reviewing the proposals and interviewing shortlisted vendors, the evaluation team selected the Sound Image proposal as the most qualified bidder. Sound Image included an acoustic modeling study to provide the best sonic performance for the three rooms with speakers. Their experience in implementing a variety of AV solutions including Q-SYS systems for performance spaces, divisible spaces in hotels and corporate installations is a standout. Their understanding of the AV design and complexity in the center's multipurpose room and auditorium was thoroughly presented during the interview process and was a determining factor in their selection. Additionally, Sound Image holds Level 2 Q-SYS training which only a handful of respondents have attained and reference checks on other like projects were highly rated. For these reasons, staff recommends Sound Image as the most qualified bidder. The Sound Image offering will provide the following services: • Consultation and system design • Equipment procurement • Acoustic modeling • Wiring and component installation • Programming and final system code • As-built drawings • Training • 1 year of support Environmental Review: This action is not subject to review under the California Environmental Quality Act (CEQA). 2 of49 October 20, 2020, Item #5Fiscal Impact: There is sufficient funding available in the Mickey Cafagna Community Center Project account (BDG0001) to award the contract. Public Notification None. Attachments: A. Standard Agreement for Services with Sound Image Reviewed/ Approved By: Wendy4{aserman Assistant City Manager 3 of49 Reviewed By: Alan Fenstermacher City Attorney Approved By: Ch~ City Manager October 20, 2020, Item #5~----·· -~---' '· ·-··• .. City of Poway ~.>,-Y;---<=-~---.... STANDARD AGREEMENT FOR SERVICES ~-::::;::;;__ :<:.-This Agreement, entered into this 20th day of October, 2020, by and between the CITY OF POWAY (hereinafter referred to as "City") and SOUND IMAGE (hereinafter referred to as "Consultant"). RECITALS WHEREAS, City desires to obtain the services of a private consultant to perform Audio Video System Installation and Integration services and WHEREAS, Consultant is an Audio Video Integrator consultant and has represented that Consultant possesses the necessary qualifications to provide such services; and WHEREAS, City has authorized the preparation of an agreement to retain the services of Consultant as hereinafter set forth. NOW, THEREFORE, IT IS MUTUALLY AGREED THAT CITY DOES HEREBY RETAIN CONSUL TANT ON THE FOLLOWING TERMS AND CONDITIONS: 1. Scope of Services. Consultant shall provide services as described in Exhibit "A" entitled "Special Provisions" attached hereto and made a part hereof. 2. Compensation and Reimbursement. City shall compensate and reimburse Consultant as provided in Exhibit "A" entitled "Special Provisions" attached hereto and made a part hereof. 3. Term of Agreement. The term of this Agreement shall be as described on Exhibit "A" entitled "Special Provisions" attached hereto and made a part hereof. 4. Termination. This Agreement may be terminated with or without cause by City. Termination without cause shall be effective only upon 60-day written notice to Consultant. During said 60-day period Consultant shall perform all consulting services in accordance with this Agreement. This Agreement may be terminated by City for cause in the event of a material breach of this Agreement, misrepresentation by Consultant in connection with the formation of this Agreement or the performance of services, or the failure to perform services as directed by City. Termination for cause shall be effected by delivery of written notice of termination to Consultant. Such termination shall be effective upon delivery of said notice. 1 4 of49 ATTACHMENT A October 20, 2020, Item #55. Confidential Relationship. City may from time to time communicate to Consultant certain information to enable Consultant to effectively perform the services. Consultant shall treat all such information as confidential, whether or not so identified, and shall not disclose any part thereof without the prior written consent of the City. Consultant shall limit the use and circulation of such information, even within its own organization, to the extent necessary to perform the services. The foregoing obligation of this Paragraph 5, however, shall not apply to any part of the information that (i) has been disclosed in publicly available sources of information; (ii) is, through no fault of Consultant, hereafter disclosed in publicly available sources of information; (iii) is now in the possession of Consultant without any obligation of confidentiality; or (iv) has been or is hereafter rightfully disclosed to Consultant by a third party, but only to the extent that the use or disclosure thereof has been or is rightfully authorized by that third party. Consultant shall not disclose any reports, recommendations, conclusions or other results of the services or the existence of the subject matter of this contract without the prior written consent of the City. In its performance hereunder, Consultant shall comply with all legal obligations it may now or hereafter have respecting the information or other property of any other person, firm or corporation. 6. Office Space and Clerical Support. Consultant shall provide its own office space and clerical support at its sole cost and expense. 7. Covenant Against Contingent Fees. Consultant declares that it has not employed or retained any company or person, other than a bona fide employee working for Consultant, to solicit or secure this Agreement, that it has not paid or agreed to pay any company or person, other than a bona fide employee, any fee, commission, percentage, brokerage fee, gift or any other consideration, contingent upon or resulting from the award or making of the Agreement. For breach of violation of this warranty, City shall have the right to annul this Agreement without liability, or, at its sole discretion, to deduct from the Agreement price or consideration, or otherwise recover the full amount of such fee, commission, percentage, brokerage fee, gift or contingent fee. 8. Ownership of Documents. All memoranda, reports, plans, specifications, maps and other documents prepared or obtained under the terms of this Agreement shall be the property of City and shall be delivered to City by Consultant upon demand. 9. Conflict of Interest and Political Reform Act Obligations. During the term of this Agreement Consultant shall not act as consultant or perform services of any kind for any person or entity whose interests conflict in any way with those of the City of Poway. Consultant shall at all times comply with the terms of the Political Reform Act and the local conflict of interest code. Consultant shall immediately disqualify itself and shall not use its official position to influence in any way any matter coming before the City in which the Consultant has a financial interest as defined in Government Code Section 87103. Consultant represents that it has no knowledge of any financial interests which would require it to disqualify itself from any matter on which it might perform services for the City. 5 of49 2 October 20, 2020, Item #5"Consultant" means an individual who, pursuant to a contract with a state or local agency: (A) Makes a governmental decision whether to: 1. Approve a rate, rule or regulation; 2. Adopt or enforce a law; 3. Issue, deny, suspend, or revoke any permit, license, application, certificate, approval, order, or similar authorization or entitlement; 4. Authorize the City to enter into, modify, or renew a contract provided it is the type of contract that requires City approval; 5. Grant City approval to a contract that requires City approval and to which the City is a party, or to the specifications for such a contract; 6. Grant City approval to a plan, design, report, study, or similar item; 7. Adopt, or grant City approval of, policies, standards, or guidelines for the City, or for any subdivision thereof; or (8) Serves in a staff capacity with the City and in that capacity participates in making a governmental decision as defined in the Political Reform Act and/or implementing regulations promulgated by the Fair Political Practices Commission, or performs the same or substantially all the same duties for the City that would otherwise be performed by an individual holding a position specified in the City's Conflict of Interest Code. DISCLOSURE DETERMINATION: ~ 1. Consultant/Contractor will not be "making a government decision" or "serving in a staff capacity" as defined in Sections A and B above. No disclosure required. D 2. Consultant/Contractor will be "making a government decision" or "serving in a staff capacity" as defined in Sections A and B above. As a result, Consultant/Contractor shall be required to file a Statement of Economic Interest with the City Clerk of the City of Poway in a timely manner as required by law. Department Director 10. No Assignments. Neither any part nor all of this Agreement may be assigned or subcontracted, except as otherwise specifically provided herein, or to which City, in its sole discretion, consents to in advance thereof in writing. Any assignment or subcontracting in violation of this provision shall be void. 11. Maintenance of Records. Consultant shall maintain all books, documents, papers, employee time sheets, accounting records, and other evidence pertaining to costs incurred and shall make such materials available at its office at all reasonable times during the contract period and for three (3) 6 of49 3 October 20, 2020, Item #5years from the date of final payment under this Agreement, for inspection by City and copies thereof shall be furnished, if requested. 12. Independent Contractor. At all times during the term of this Agreement, Consultant shall be an independent contractor and shall not be an employee of the City of Poway. City shall have the right to control Consultant only insofar as the results of Consultant's services rendered pursuant to this Agreement; however, City shall not have the right to control the means by which Consultant accomplishes such services. 13. Licenses, Perm its, Etc. Consultant represents and declares to City that it has all licenses, permits, qualifications, and approvals of whatever nature that are legally required to practice its profession. Consultant represents and warrants to City that Consultant shall, at its sole cost and expense, keep in effect at all times during the term of this Agreement, any license, permit, or approval which is legally required for Consultant to practice its profession. 14. Consultant's Insurance. Consultant shall provide insurance as set forth in Exhibit "A" entitled "Special Provisions" attached hereto and made a part hereof. 15. Indemnification. (a) For Claims (as defined herein) other than those alleged to arise from Consultant's negligent performance of professional services, City and its respective elected and appointed boards, officials, officers, agents, employees and volunteers (individually and collectively, "lndemnitees") shall have no liability to Consultant or any other person for, and Consultant shall indemnify, protect and hold harmless lndemnitees from and against, any and all liabilities, claims, actions, causes of action, proceedings, suits, damages, judgments, liens, levies, costs and expenses, including reasonable attorneys' fees and disbursements (collectively "Claims"), which lndemnitees may suffer or incur or to which lndemnitees may become subject by reason of or arising out of any injury to or death of any person(s), damage to property, loss of use of property, economic loss or otherwise occurring as a result of Consultant's negligent performance under this Agreement, or by the negligent or willful acts or omissions of Consultant, its agents, officers, directors, sub-consultants or employees. (b) For Claims alleged to arise from Consultant's negligent performance of professional services, lndemnitees shall have no liability to Consultant or any other person for, and Consultant shall indemnify and hold harmless lndemnitees from and against, any and all Claims that lndemnitees may suffer or incur or to which lndemnitees may become subject by reason of or arising out of any injury to or death of any person(s), damage to property, loss of use of property, economic loss or otherwise to the extent occurring as a result of Consultant's negligent performance of any professional services under this Agreement, or by the negligent or willful acts or omissions of Consultant, its agents, officers, directors, sub-consultants or employees, committed in performing any of professional services under this Agreement. For Claims alleged to arise from Consultant's professional services, Consultant's defense obligation to lndemnitees shall include only the reimbursement of reasonable defense costs and attorneys' fees to the extent caused by Consultant's negligence. 7 of49 4 October 20, 2020, Item #5( c) The foregoing obligations of Consultant shall not apply to the extent that the Claims arise from the sole negligence or willful misconduct of City or its elected and appointed boards, officials, officers, agents, employees and volunteers. (d) In any and all Claims against City by any employees of the Consultant, anyone directly or indirectly employed by it or anyone for whose acts it may be liable, the indemnification obligation under this Section 15 shall not be limited in any way by any limitation on the amount or type of damages, compensation or benefits payable by or for the Consultant under worker's compensation acts, disability benefit acts or other employee benefit acts. (e) Consultant shall, upon receipt of written notice of any Claim, promptly take all action necessary to make a claim under any applicable insurance policy or policies Consultant is carrying and maintaining; however, if Consultant fails to take such action as is necessary to make a claim under any such insurance policy, Consultant shall reimburse City for any and all costs, charges, expenses, damages and liabilities incurred by City in making any claim on behalf of Consultant under any insurance policy or policies required pursuant to this Agreement. (f) The obligations described in Section 15(a) through (e) above shall not be construed to negate, abridge or otherwise reduce any other right or obligation of indemnity which would otherwise exist as to any party or person indemnified pursuant to this Section 15. (g) The rights and obligations of the parties described in this Section 15 shall survive the termination of this Agreement. 16. Assumption of Risk. Except for injuries to persons caused by the willful misconduct of any lndemnitee and not covered by insurance maintained, or required by this Agreement to be maintained, by Consultant: (a) Consultant hereby assumes the risk of any and all injury and damage to the personnel (including death) and property of Consultant that occurs in the course of, or in connection with, the performance of Consultant's obligations under this Agreement, including but not limited to Consultant's Scope of Services; and (b) it is hereby agreed that the lndemnitees are not to be liable for injury or damage which may be sustained by the person, goods or property of Consultant or its employees in connection with Consultant's performance its obligations under this Agreement, including but not limited to Consultant's Scope of Services. 17. Consultant Not an Agent. Except as City may specify in writing, Consultant shall have no authority, expressed or implied, to act on behalf of City in any capacity whatsoever as an agent. Consultant shall have no authority, expressed or implied, pursuant to this Agreement to bind City to any obligation whatsoever. 18. Personnel. Consultant shall assign qualified and certified personnel to perform requested services. The City shall have the right to review and disapprove personnel for assignment to Poway projects. City shall have the unrestricted right to order the removal of any person(s) assigned by Consultant by giving oral or written notice to Consultant to such effect. 8 of49 5 October 20, 2020, Item #5Consultant's personnel shall at all times comply with City's drug and alcohol policies then in effect. 19. Notices. Notices shall be given as described on Exhibit "A" entitled "Special Provisions" attached hereto and made a part hereof. 20. Governing Law, Forum Selection and Attorneys' Fees. This Agreement shall be governed by, and construed in accordance with, the laws of the State of California. Each party to this Agreement consents to personal jurisdiction in San Diego County, California, and hereby authorizes and accepts service of process sufficient for personal jurisdiction by first class mail, registered or certified, postage prepaid, to its address for giving notice as set forth in Exhibit "A" hereto. Any action to enforce or interpret the terms or conditions of this Agreement shall be brought in the Superior Court in San Diego County, Central Division, unless the parties mutually agree to submit their dispute to arbitration. Consultant hereby waives any right to remove any such action from San Diego County as is otherwise permitted by California Code of Civil Procedure section 394. The prevailing party in any such action or proceeding shall be entitled to recover all of its reasonable litigation expenses, including its expert fees, attorneys' fees, courts costs, arbitration costs, and any other fees. Notwithstanding the foregoing, in the event that the subject of such an action is compensation claimed by Consultant in the event of termination, Consultant's damages shall be limited to compensation for the 60-day period for which Consultant would have been entitled to receive compensation if terminated without cause, and neither party shall be entitled to recover their litigation expenses. 21. Gender. Whether referred to in the masculine, feminine, or as "it," "Consultant" shall mean the individual or corporate consultant and any and all employees of consultant providing services hereunder. 22. Counterparts. This Agreement (and any amendments) may be executed in multiple counterparts, each of which shall be deemed an original, but all of which, together, shall constitute one and the same instrument. Documents delivered by telephonic facsimile transmission shall be valid and binding. 23. Entire Agreement. This Agreement shall constitute the entire understanding between Consultant and City relating to the terms and conditions of the services to be performed by Consultant. No agreements, representations or promises made by either party, whether oral or in writing, shall be of any force or effect unless it is in writing and executed by the party to be bound thereby. 24. Certification and Indemnification Regarding Public Employees' Retirement Law/Pension Reform Act of 2013. Contractor hereby certifies that all persons providing services to City by Contractor are not current members of the California Public Employees' Retirement System (CalPERS) and shall not become members of CalPERS while providing services to City. 9 of49 6 October 20, 2020, Item #5Contractor further provides that in the event Contractor assigns a retired annuitant receiving a pension benefit from CalPERS to perform services for City, the retired annuitant is in full compliance with Government Code section 7522.56. A copy of Government Code section 7522.56 is attached hereto as Exhibit "B." Further, Contractor hereby fully and unconditionally indemnifies City from all penalties, fees, employer and employee contributions, or any other assessments imposed by CalPERS in the event CalPERS determines the person assigned by Contractor to provide services to City has been misclassified. 25. Severability. If any provision of this Agreement is determined by any court of competent jurisdiction or arbitrator to be invalid, illegal, or unenforceable to any extent, that provision shall, if possible, be construed as though more narrowly drawn, if a narrower construction would avoid such invalidity, illegality, or unenforceability or, if that is not possible, such provision shall, to the extent of such invalidity, illegality, or unenforceability, be severed, and the remaining provisions of this Agreement shall remain in effect. (Remainder of page intentionally left blank) 10 of 49 7 October 20, 2020, Item #5IN WITNESS WHEREOF, the parties hereto have duly executed this Agreement on the date first above written. CITY OF POWAY By: __________ _ Chris Hazeltine, City Manager Date: -----------ATTEST: Vaida Pavolas, City Clerk APPROVED AS TO FORM: By:-------------Alan Fenstermacher, City Attorney 11 of 49 SOUND IMAGE 8 By:------------Ralph Wagner, CFO Date: ------------ October 20, 2020, Item #5A. "SPECIAL PROVISIONS" EXHIBIT "A" Scope of Services. Consultant agrees to perform audio visual system design and installation services as required by City, for the Mickey Cafagna Community Center further described in the following documents: Sound Image proposal dated September 3, 2020, City of Poway Community Center AV System RFP Addendum #1 and Addendum #2 which are included in this document as Attachment 1, and incorporated by reference, as if its contents were fully set forth herein. Consultant shall provide the necessary qualified personnel to perform the services. B. Compensation and Reimbursement. City shall pay Consultant a fee in accordance with the Proposal submitted with the quote dated September 3, 2020, which is included in this document as Attachment 2. Total fee is not to exceed total contract amount of $168,773.00. Consultant's fee shall include and Consultant shall be responsible for the payment of all federal, state, and local taxes of any kind which are attributable to the compensation received. C. Term of Agreement. This Agreement shall be effective from the period commencing October 20, 2020, and ending June 30, 2022, unless sooner terminated by City as provided in the section of this Agreement entitled "Termination." This Agreement may be extended for up to two additional one-year periods upon approval in writing of the City Manager and Consultant. Upon expiration or termination of this Agreement, Consultant shall return to City any and all equipment, documents or materials and all copies made thereof which Consultant received from City or produced for City for the purposes of this Agreement. D. Consultant's Insurance. 1. Coverages: Consultant shall obtain and maintain during the life of this Agreement all of the following insurance coverages: (a) Comprehensive General Liability. including premises-operations, products/completed, broad form property damage, and blanket contractual liability with the following coverages: General Liability $1,000,000 Bodily Injury and Property Damage combined each occurrence and $2,000,000 aggregate. (b) Automobile Liability. including owned, hired, and non-owned vehicles: $1,000,000 combined single limit. (c) Consultant shall obtain and maintain, during the life of the Agreement, a policy of Professional Errors and Omissions Liability Insurance with policy limits of not less than $1,000,000 combined single limits, per claim and annual aggregate. 12 of 49 1 October 20, 2020, Item #5(d) Workers' Compensation insurance in statutory amount. All of the endorsements which are required above shall be obtained for the policy of Workers' Compensation insurance. 2. Endorsements: Endorsements shall be obtained so that each policy contains the following three provisions: (a) Additional Insured. (Not required for Professional Errors and Omissions Liability Insurance or Workers' Compensation.) "City of Poway and its elected and appointed boards, officers, agents, and employees are additional insureds with respect to this subject project and contract with City." (b) Notice. "Said policy shall not terminate, nor shall it be canceled, until thirty (30) days after written notice is given to City." (c) Primary Coverage. "The policy provides primary coverage to City and its elected and appointed boards, officers, agents, and employees. It is not secondary or in any way subordinate to any other insurance or coverage maintained by City." 3. Insurance Certificates: Consultant shall provide City certificates of insurance showing the insurance coverages described in the paragraphs above, in a form and content approved by City, prior to beginning work under this Agreement. E. Notices. All notices, billings and payments hereunder shall be in writing and sent to the following addresses: To City: To Consultant: 13 of 49 2 City of Poway P.O. Box 789 Poway, CA 9207 4 Sound Image 2425 Auto Park Way Escondido, CA 92029 October 20, 2020, Item #5EXHIBIT "B" Cal Gov Code§ 7522.56 Deering's California Codes are current through all 1016 chapters of the 2018 Regular Session and the November 6, 2018 Ballot Measures. Deering's California Codes Annotated> GOVERNMENT CODE> Title 1 General> Division 7 Miscellaneous > Chapter 21 Public Pension and Retirement Plans > Article 4 California Public Employees' Pension Reform Act o/2013 § 7522.56. Provisions applicable to person receiving pension benefit from public retirement system; Section supersedes conflicting provisions (a)This section shall apply to any person who is receiving a pension benefit from a public retirement system and shall supersede any other provision in conflict with this section. (b) A retired person shall not serve, be employed by, or be employed through a contract directly by, a public employer in the same public retirement system from which the retiree receives the benefit without reinstatement from retirement, except as permitted by this section. (c) A person who retires from a public employer may serve without reinstatement from retirement or loss or interruption of benefits provided by the retirement system upon appointment by the appointing power of a public employer either during an emergency to prevent stoppage of public business or because the retired person has skills needed to perform work of limited duration. ( d)Appointments of the person authorized under this section shall not exceed a total for all employers in that public retirement system of 960 hours or other equivalent limit, in a calendar or fiscal year, depending on the administrator of the system. The rate of pay for the employment shall not be less than the minimum, nor exceed the maximum, paid by the employer to other employees performing comparable duties, divided by 173.333 to equal an hourly rate. A retired person whose employment without reinstatement is authorized by this section shall acquire no service credit or retirement rights under this section with respect to the employment unless he or she reinstates from retirement. (e) 14 of 49 (l)Notwithstanding subdivision ( c ), any retired person shall not be eligible to serve or be employed by a public employer if, during the 12-month period prior to an appointment described in this section, the retired person received any unemployment insurance compensation arising out of prior employment subject to this section with a public employer. A retiree shall certify in writing to the employer upon accepting an offer of employment that he or she is in compliance with this requirement. October 20, 2020, Item #5City of Poway Managed Security Services Provider RFP (2)A retired person who accepts an appointment after receiving unemployment insurance compensation as described in this subdivision shall terminate that employment on the last day of the current pay period and shall not be eligible for reappointment subject to this section for a period of 12 months following the last day of employment. (f)A retired person shall not be eligible to be employed pursuant to this section for a period of 180 days following the date of retirement unless he or she meets one of the following conditions: (l)The employer certifies the nature of the employment and that the appointment is necessary to fill a critically needed position before 180 days have passed and the appointment has been approved by the governing body of the employer in a public meeting. The appointment may not be placed on a consent calendar. (2) (A)Except as otherwise provided in this paragraph, for state employees, the state employer certifies the nature of the employment and that the appointment is necessary to fill a critically needed state employment position before 180 days have passed and the appointment has been approved by the Department of Human Resources. The department may establish a process to delegate appointing authority to individual state agencies, but shall audit the process to determine if abuses of the system occur. If necessary, the department may assume an agency's appointing authority for retired workers and may charge the department an appropriate amount for administering that authority. (B)For legislative employees, the Senate Committee on Rules or the Assembly Rules Committee certifies the nature of the employment and that the appointment is necessary to fill a critically needed position before 180 days have passed and approves the appointment in a public meeting. The appointment may not be placed on a consent calendar. (C)For employees of the California State University, the Trustees of the California State University certifies the nature of the employment and that the appointment is necessary to fill a critically needed position before 180 days have passed and approves the appointment in a public meeting. The appointment may not be placed on a consent calendar. (3)The retiree is eligible to participate in the Faculty Early Retirement Program pursuant to a collective bargaining agreement with the California State University that existed prior to January 1, 2013, or has been included in subsequent agreements. ( 4)The retiree is a public safety officer or firefighter hired to perform a function or functions regularly performed by a public safety officer or firefighter. (g)A retired person who accepted a retirement incentive upon retirement shall not be eligible to be employed pursuant to this section for a period of 180 days following the date of retirement and subdivision (f) shall not apply. 4 15 of 49 October 20, 2020, Item #5City of Poway Managed Security Services Provider RFP (h)This section shall not apply to a person who is retired from the State Teachers' Retirement System, and who is subject to Section 24214, 24214.5 or 26812 of the Education Code. (i)This section shall not apply to (1) a subordinate judicial officer whose position, upon retirement, is converted to a judgeship pursuant to Section 69615, and he or she returns to work in the converted position, and the employer is a trial court, or (2) a retiree of the Judges' Retirement System or the Judges' Retirement System II who is assigned to serve in a court pursuant to Section 68543.5. History Added Stats 2012 ch 296 § 15 (AB 340), effective January 1, 2013. Amended Stats 2013 .ch 528 § 11 (SB 13), effective October 4, 2013 (ch 528 prevails); ch 76 § 75 (AB 383), effective January 1, 2013; Stats 2014 ch 238 § 1 (AB 2476), effective January 1, 2015. Annotations Notes Amendments: Note-Amendments: 2013 Amendment: Substituted (1) "have passed" for "has passed" in the first sentence of subds (f)(l) and (f)(2); (2) "or firefighter hired to perform a function or functions regularly performed by a public safety officer or firefighter" for "of firefighter" in subd (f)(4); and (3) "Judges' Retirement System" for "Judges' Retirement System I" in subd (i). 5 16 of 49 October 20, 2020, Item #5ATTACHMENT 1 EXPERIENCE THE DIFFERENCE City of Poway Community Center AV System Bid Proposal for RFP 21-007 Submitted To: City of Poway -IT Division Attn: Brad Rosen 13325 Civic Center Drive Poway, CA 92046 Prepared by: Jake E. Henricksen I Sound Image E I jhenricksen@sound-image.com TI 760.737.3900 Date: Revision: September 3, 2020 1.0 City of Poway -Community Center AV System Bid Proposal for RFP 21-007 REV 1.0 17 of 49 9/3/2020 1 of 11 October 20, 2020, Item #5SOUND Greetings, The following is an all-inclusive design-build proposal for a multi-room AV system at the new Mickey Cafagna Community Center. After careful review of your RFP, we at Sound Image feel that we would be an excellent fit for this project and are delighted to provide this proposal for your consideration! This proposal includes further design development and engineering, construction documentation and as-builts, equipment procurement, installation, programming, commissioning, and training for a turn-key AV system that will meet or exceed your RFP requirements. In addition to this proposal, we have attached other documents listed below. Your RFP requires some of these; others are our standard inclusions. Our process is driven by the idea that AV systems should be easy to use and transparent, allowing the audience to experience AV content without perceiving the AV system. We believe that early coordination and communication help deliver more value and higher quality systems to owners when we work as design consultants and project managers first, integrators second. Thanks again for allowing Sound Image to provide this proposal! After you've had a chance to review, feel free to contact me directly if you have any questions . p Jake Henricksen Design Consultant I Sound Image jhenricksen@sound-image.com Direct Cell: 760.912.5789 Office: 760.737.3900 City of Poway -Community Center AV System Bid Proposal for RFP 21-007 REV 1.0 18 of 49 9/3/2020 2 of 11 October 20, 2020, Item #5SOUND Attached Documents: Additional documents are attached as follows: -Poway Community Center AV System -RFP 21-007 -Sound Image, REV 1.0 (This Document) -Bill of Materials / Proposal 2009CPCA --Sound Image I Integration Division Corporate Profile Addendum Acknowledgement: Sound Image has received the the following addendum and confirms that pricing included herein includes any changes from these addendum: -Community Center AV System -RFP 21-007 -Addendum 1 City of Poway -Community Center AV System Bid Proposal for RFP 21-007 REV 10 19 of 49 9/3/2020 3 of 11 October 20, 2020, Item #5SOUND Project Narrative: The Mickey Cafagna Community Center is a new building intended for multipurpose use by the residents of Poway. AV systems will be required in multiple rooms to accommodate many different types of presentations and recreational services provided by the city. These rooms include an Auditorium with divisible Meeting Rooms, a divisible Multipurpose Room, and a Dance Studio. Each room will require slightly different audio and video equipment, but will be tied to a central DSP, video matrix, and control system. Sound Image will provide further design development and engineering to bring the provided basis of design to a fully constructible system. This includes consultation and budgetary review, recommendations for value engineering and performance enhancement, CAD deliverables such as technical power infrastructure, low-voltage conduit infrastructure, riser diagram, back box sizing and locations, custom wall plates and panel designs, equipment layouts, architectural AV equipment integration details, single-line diagrams, cable schedules and wire numbering conventions, and other construction documents as required. Also included is design of structural backing and attachment for all AV equipment with wet-stamped structurally engineered drawings. This will allow coordination with the design and construction team early on in the process, minimizing excessive change orders to accommodate AV system infrastructure needs. All rooms that have AV systems will be provided with a dedicated assistive listening system (ALS) per ADA code with a secondary WiFi based ALS system. The WiFi system will be capable of 8 discrete channels streaming to a free smartphone app downloaded on personal devices. The ALS system will also include a centralized multi-port charging station. The Auditorium Meeting Room(s) will include a single projector with ambient light rejecting projection screen, room dividing sound reinforcement system, local HDMI and audio inputs/outputs for both dividable rooms, wireless video presentation, wireless microphone remote antenna system with up to 4 transmitters, and custom programmed touchscreen control system. All inputs and outputs will be network based and tied to a centrally located QSC O-SYS Core for audio DSP, video matrix switching, and control. City of Poway -Community Center AV System Bid Proposal for RFP 21-007 REV 1.0 20 of 49 9/3/2020 4 of 11 October 20, 2020, Item #5SOUND Project Narrative Continued: The Multipurpose Room will include dual projectors using the wall as a projection surface* (See Note Below), room dividing sound reinforcement system, local HDMI and audio inputs/outputs for both dividable rooms, wireless video presentation, wireless microphone remote antenna system with up to 4 transmitters, and custom programmed touchscreen control system. All inputs and outputs will be network based and tied to a centrally located QSC O-SYS Core for audio DSP, video matrix switching, and control. The Dance Studio will include a sound reinforcement system with Bluetooth and analog audio inputs and dedicated wall mounted equipment rack for amplifier. Sound Image would like to explore the idea of locating this amplifier in the main AV equipment rack if awarded the contract, but have held the equipment rack cost in this proposal. A centrally located AV equipment rack will house the O-SYS Core with network video encoder/decoders for audio DSP, video matrix switching, and control, as well as amplifiers for the loudspeakers. Distribution of video sources and control signals to/ from the O-SYS Core will be via DTP TX/RX. Audio distribution will be via Dante over IP. Sound Image recommends a segregated network (VLAN or dedicated network) for all AV network traffic. Careful considerations must be made in regards to OFE network switches, deployment, and aggregation with other network traffic to maintain AV network performance. An OFE cable box and wireless presentation system will be sources local to the AV equipment rack. Wireless microphone receivers, antenna combining/zone control, and ALS systems will be co-located in the AV equipment rack. Sound Image is recommending and has provided costs/equipment necessary for an improved wireless microphone antenna system design for each room. This will utilize a passive antenna combiner with zone control and remote antennas from RF Venue. In practice, 1/2 wave antennas do not function properly without a significant ground plane and spacing of these antennae becomes critical and frequency dependent. We have had much better results using the Diversity Fin (DFIN) antenna from RF Venue in these types of distributed systems. The polarized Dipole/LPDA antenna combination provides excellent RF reception without the pitfalls of inconsistently spaced 1/2 wave antennae. * Note: Sound Image recommends using dedicated and engineered projection surfaces when possible as the reflection of light off a wall does not have the same performance as a purpose built projection surface. However, we understand this may be a value engineering decision based on budget and have not included projection screens in this proposal. We can explore options and ideas further if awarded a contract and would be recommending, at a minimum, to provide infrastructure and backing for future projection screens. City of Poway -Community Center AV System Bid Proposal for RFP 21-007 REV 1.0 21 of 49 9/3/2020 5 of 11 October 20, 2020, Item #5SOUND Scope of Work: 1. Provide consultation, design review, coordination, and project management to further develop the AV system design and provide construction team with all necessary AV infrastructure details. Provide value engineering and propose performance improvements, as required. 2. Provide acoustic modeling of sound system performance and coverage. Verify performance of basis of design and provide feedback for improved performance. 3. Provide engineering and CAD deliverables for submittals, design verification, coordination, and construction. 4. Provide wet-stamped structurally engineered drawings of AV equipment attachment to building and seismic supports for all overhead and wall mounted equipment, as required. 5. Provide project management and coordination with design and construction team, other trades, and city staff for the duration of the project. 6. Provide equipment procurement, warehousing, pre-build and verification, as well as other off site shop services at our Escondido location as required. 7. Provide construction administration and verification of AV infrastructure as building construction progresses. Identify any deficiencies and provide progress reporting to design team and city staff, as required. 8. Design, fabricate, furnish, and install custom AV wall plates and panels with laser engraved labels. Finish TBD and coordinated with architect/design team. 9. Furnish and install all equipment, wiring, and cables listed in the Bill of Materials and any additional or alternate equipment identified during design development. 1 o. Provide custom DSP and control system programming including custom user control interface designs and graphical elements. Coordinate with owner on design iterations to minimize re-programming. 11. Provide testing and verification of all installed cabling including wire numbering confirmation and documentation. 12. Provide system startup and commissioning for all equipment and systems provided herein. 13. Provide training on operation of all equipment and systems provided herein. 1 L1_ Provide 1-year warranty on all equipment and workmanship. Includes one programming touch-up after 90 days of use, as required. City of Poway -Community Center AV System Bid Proposal for RFP 21-007 REV 1.0 22 of 49 9/3/2020 6 of 11 October 20, 2020, Item #51 1 / 1., i ~) SOUND Bill of Materials: See Attached Proposal 2009CPCA Proposed Schedule: (Scheduling may very depending on contract execution date, procurement, and construction progress. Complete schedule to be provided once under contract.) Mickey Cafagna Community Center + Team -Engineering Submittals As-builts Shop Fabication Field Install Conduit & Backboxes Complete (By Others) Pre-Wire Building Ready for Equipment Equipment Installation Rack Terminations Building Power Complete (By Others) Testing/Commissioning Training City of Poway -Community Center AV System Bid Proposal for RFP 21-007 REV 1.0 23 of 49 1001/20 O'll2fJ/21 10/01/20 02/26/21 10/01/20 10/07/20 02/22/21 02/26/21 01/04/21 01/08/21 12/11/20 02/19/21 12/11/20 12/11/20 12/14/20 12/18/20 01/08/21 01/08/21 01/18/21 01/29/21 01/25/21 01/29/21 02/05/21 02/05/21 02/08/21 02/12/21 02/18/21 02/19/21 9/3/2020 • • I --. 107d Mickey 107d , Engine 5d Submittals 5d As-buil 5d Shop Fabication 51d Field lnsi 0 ♦Conduit & Backboxes Com~ 5d Pr~-Wire 0 ♦Building Ready for E 10d Equipment Ins 5d Rack T ermina1 0 ♦Building Pov. 5d Testing/Co 2d Training 7 of 11 October 20, 2020, Item #5SOUND Education & Certifications of Project Team Jake Henricksen -Design Consultant & Account Executive Employed Since: 2017 Certifications: Symmetrix Symnet; 0-SYS Level 2; Renkus-Heinz lconyx; Yamaha PM, M7, CL; DiGiCo; d&b Audiotechnic ArrayCalc, NoiseCalc; EASE; SMAART; Dante Level 1 & 2 Education: AA -Music Performance; Riverside Community College Acoustic Design, Music Business, Audio Electronics; Berklee College of Music Affiliations: Audio Engineering Society (AES) Acoustical Society of America (ASA) Jeff Schmitz -Director of Engineering Employed Since: 2003 Education: Five years, non-degree track in Business Administration and Audio in Media; San Diego State University; Palomar College; UCSD; Grossmont College Certifications: Manufacturing Technology; AutoCAD Levels 1 - 3 and Advanced 30 Modeling; Revit I & II -BIM Software; BSS Soundweb, Rane; Ivie; MediaMatrix; AMX Installer; Photoshop Ryan Ash, MDE, CTS, CTS-D -Senior Programmer & Project Engineer Employed Since: 2005 Education: BA -Music; California Baptist University Certifications: CTS, CTS-O; AMX Programmer; Crestron Programmer; Extron AV Associate; Symetrix Symnet; Digidesign O-Show; AutoCAD Levels 1 -3; Q-SYS Level 2 Solomon Peck, CTS, CTS-D -Project Engineer Employed Since: 2016 Education: AS -Business Administration; Mira Costa College AA -Mechanical Design; Mira Costa College Certifications: CTS, CTS-O; 0-SYS Level 1; Extron AV Associate; Dante Level 1 & 2 Alex Pappas, CTS -Project Manger & Lead Installer Employed Since: 2017 Certifications: CTS; 0-SYS Level 1; Extron AV Associate; Dante Level 1, 2, & 3; CPR Certified; OSHA; Scissor Lift City of Poway -Community Center AV System Bid Proposal for RFP 21-007 REV 1.0 24 of 49 9/3/2020 8 of 11 October 20, 2020, Item #5SOUND Recent Similar Projects & References: (Please see our Corporate Profile for an extensive list of recent and current projects, or contact us directly for more specific information.) Casta Del Sol, Vista Room -Mission Viejo, CA Job Dates: 2018-2019 Job Value: $125K Scope: Community Recreation Room AV upgrades including O-SYS DSP & custom control, sound reinforcement system, video projection system & motorized projection screen, acoustic treatment design. Contact: Tim Roller -Facilities Manager troller@powerstonepm.com Recreation Centers of Sun City West -Sun City West, AZ Job Dates: 2017-2020 Job Value: $200K -Multiple Contracts Scope: Multiple Community Recreation Room and Ballroom AV upgrades including Symetrix DSP & custom control, sound reinforcement systems, distributed AV systems, video projection systems & motorized projection screens. Contact: John D'Ottaio -Recreation Manager john.d@rcscw.com Trilogy at Power Ranch -Gilbert, AZ Job Dates: 2017-2020 Job Value: $450K -Multiple Contracts Scope: Multiple Community Recreation Rooms and Ballroom AVL upgrades including audio DSP & custom control, sound reinforcement systems, distributed AV systems, video projection systems, motorized projection screens, theatrical lighting, theatrical draperies, & softgoods. Contact: Dave Brown -Project Manager anndavid71@q.com St. Bartholomew's Episcopal Church -Poway, CA Job Dates: 2020 Job Value: $85K -Multiple Contracts Scope: Sanctuary remodel AV & acoustic design, sound reinforcement system, video braodcast/streaming systems, projection systems, and sound reinforcement systems installation. Contact: Mark Davis -Project Manager davis@vmarch.net Poway USD High Schools -Poway, CA Job Dates: 2020 Job Value: $125K -Multiple Contracts Scope: Design & installation of edge blended environmental projection systems at Del Norte, Rancho Bernardo, and My. Carmel High Schools. Design & installation of 4K cinema projector & upgraded 40' motorized projection screen at Rancho Bernardo High School. Contact: Jeremy Martin -Career Education Specialist jemartin@powayusd.com Ross Kallen -Cinema & Media Arts rkallen@powayusd.com City of Poway -Community Center AV System Bid Proposal for RFP 21-007 REV 1.0 25 of 49 9/3/2020 9 of 11 October 20, 2020, Item #5SOUND Assumptions and Exclusions: 1. Sound Image assumes electrical work, including but not limited to: low-voltage conduit, raceway, back boxes, service panels, high voltage wiring & fixtures necessary for AVL infrastructure is provided by others. 2. Any equipment, work, or other systems not detailed in proposal 2009CPCA and this agreement are excluded. 3. Data networks (other than any AVL networking outlined in the specifications), telecom, security, life safety, satellite, cable TV, and other low voltage infrastructure is excluded from this bid proposal. 4 Custom AV integrated millwork, speaker grilles, molding, trim, cabinets, furniture, and casework design and manufacturing are excluded from this scope unless otherwise noted. 5. Excludes any structural modifications, backing, and bracing necessary to mount AV rigging and equipment to existing/planned structural members. 6. Excludes engineering, installation, mounting, and setup of OFE network equipment, including wireless access points (WAP's). 7. Excludes specific bid and project bonds outside of our standard license bonds. City of Poway -Community Center AV System Bid Proposal for RFP 21-007 REV 1.0 26 of 49 9/3/2020 10 of 11 October 20, 2020, Item #5Bid Summary: Equipment & Materials .......................................................... $105, 142.11 Allowance for Design Variance ............................................... $ 2,000.00 Labor ................................................................................. $ 51,200.00 Extras (Lift & Tool Rental) ....................................................... $ 945.05 Shipping & Handling ............................................................ $ 1,182.33 Sales Tax ............................................................................ $ 8,303.51 TOTAL BID ......................................................................... $168,773.00 City of Poway -Community Center AV System Bid Proposal for RFP 21-007 REV 1.0 27 of 49 9/3/2020 11 of 11 October 20, 2020, Item #5r·•, Community Center AV System RFP 21-007 --) .· l'trt;::-;,~·-~ ,;,~"-~:' Addendum #1 Job site review: There will be no job walk available for this project at this time. Clarifications: i. Design and price: Reliability, simplicity of installation, use and support are all important consderations. Best value is better than lowest cost, low reliability, difficult troubleshooting and poor user experience. The antenna design may need more attention. The IT depa~tment does support its AV systems and will be learning as much about it to provide normal support and guide any future modifications. ii. Substitutions: City is specific to the QSC Q-SYS system so that it covers the audio engine and control with one unit essentially, the speakers were selected for the quality of sound, projectors for the image quality from Epson, the mic system and amplifiers -will be hooked up to the system using CAT cable instead of having multiple audio cables, etc. a. CAT transmitters: While the City has been using Extron extensively, we are open to using Atlona if the reliability and features are comparable or better. We believe that there are units that include USB, Ethernet, RS-232, and HDMI all over single CAT cable. b. Video signals: This system may be used to play movies for Teen events iii. Location of the four (4) QSYS NV-32 equipment: I will want to have them all in the rack and then extend the hdmi and RS232 to the projectors. Two approaches, the goal will be to have a more stable, dependable system. a. Use HDBT and IP control for the projectors b. Extend using HDBT or DTP and convert to HDMI and use RS-232 over CAT cable for control iv. NV-32 inputs and Wall Inputs: Two of the NV-32 will be set for encoding, the combined 6 availble inputs will be used the Auditorium and Multipurpose room which will have two wall inputs, this is also seen in the touchscreen mockups. a. Auditorium (Front and Back), Multipurpose (Left and Right) b. There is only one Cox cable box and one Cynap for the system, they will be shared between the two rooms and located in the rack. (It should be confirmed that when the NV-32 is used as an encoder, any sources can be sent to the NV-32 on the network set as decoders.) v. Cox and Cynap sources: There are only 1 of each that can be selected and shared between the Auditorium and Multipurpose rooms. The physical equipment is in the rack. a. If there is an opportunity to use any type of USB extension over the CAT transmitters to provide keyboard or mouse input to the Cynap, that would be a desireable function. vi. UnDX210+ wall plate: Outputs should be ready to provde the mixed audio signal at anytime. They could be used for the subwoofers, or when rental clients want to use the built-in system and amplify it using their own larger system. Inputs can be used to plug in additional sources that could be mixed into the room's built-in audio. vii. KS112 Subwoofer Use: The subwoofers can be used in any of the rooms at any time by connecting to the unDX210+ wall plate. The subwoofers may be stored in any of the storage rooms. viii. Antenna extensions: Mies and Listen RF recievers should have good signal in Auditorium and Multipurpose Rooms, your design should clarify how that will be achieved. Suggestions welcomed. 28 of 49 October 20, 2020, Item #5City of Poway Community Center AV System RFP 21-007 ix. Listen Battery Charger Model: Replace the incompatible LA-480 with the LA-38112-unit charger. Questions: 1. Which spaces are to get the QSC KS112 subwoofers? a. All 3 spaces that have the unDX210+ plates should be able to use the subs. Subs might not be used during normal meetings. The audio quality should be sufficient without subs. 2. The back half of the room will then be served by an existing {OFE) TV on a cart that will connect to the system via HOM/ wall plate input and HOM/ wall plate output with the ceiling speakers reinforcing the audio for that particular source and mixing in mies. a. Are there other components on the OFE cart other the TV? i. No, it is basically a cart with a TV on it. We could also use a projector with an HDMI input. b. Is the HOM/ output plate a means of getting other system sources to display on the TV on the OFE cart? i. The back half of the Auditorium will have wall plates for both and input and output. The output plate will do exactly that -allow the presenter to use any source in the system, and have it amplified and mixed with selected microphones over the section of the speakers in the back half ofthe Auditorium. 3. There are (4) Qsys NV-32 end points listed on equipment list. 29 of 49 a. Please provide further clarification as to how these devices are intended to be used? i. Two will be set as encoders, two will be set as decoders. They will be installed in the rack. All sources and projectors will be connected via CAT extenders ii. If in the future the City decides to switch to 4K signal at the projectors, additional NV32 units will be added so that each projector has a dedicated NV32 decoder. b. Assumption using auditorium as an example: i. NV-32, set up as encoder, has 3 HOM/ inputs that can accept signal from Cox cable set top box, Cynap wireless presenter and one (1) HOM/ TX/RX wall plate kit and route them over them over the QSYS network. A second NV-32, set up as decoder can distribute video (from sources above) via HOM/ output and control (via RS-232) signal to the auditorium projector. ii. This set up is repeated for the multipurpose room with the exception that the NV-32 decoder's second HOM/ output would feed the second projector. iii. If this assumption is correct, this method would only support three HOM/ sources in each room. 1. The understanding is that when the NV32 is set as an encoder, all sources are going to be available to NV32 decoders on the network. Page 2 of 4 October 20, 2020, Item #5City of Poway Community Center AV System RFP 21-007 4. Please clarify the quantity of HDMI wall plate transmitter/receiver kits (Atlona AT-OME0EX-WP-Kit) for the auditorium and multipurpose room. a. Equipment list says 4, but the video distribution described above only support three (3) sources (one HDMI wall plate, Cox and Cynap) and would not accommodate a second HDMI wall plate in both the auditorium and multipurpose room. i. Extron or Atlona may be used for this design to extend signals. ii. Two sources in each room will be extended back to the rack 1. total of 4 wall plate transmitters extending back to rack (installed in rack) iii. The Cox box and Cynap will be in the rack and connect via HDMI. This should mean that there are 6 total sources and 6 total inputs on the 2 NV32 encoders. iv. The three (3) projectors will either be connected via HDBT and use their native input and 3 HDBT transmitters in the rack 1. OR DTP transmitters and receiver pairs and convert back to HDMI 2. The Auditorium receiver/output wall plate (is like the 4th projector) in the back of the room will provide HDMI connectivity for a projector or tv on cart. 5. How are the two (2) HDBT or DTP receivers and two (2) HDBT or DTP transmitters being used in the system. a. Hopefully the answers above clarify this question. 6. How are audio controls for Dance Room being handled? 30 of 49 a. The connected device: phone, tablet, computer, etc. will be the volume control for the Dance Room. We expect that the amplification will be set to a safe level that will prevent equipment damage. Page 3 of 4 October 20, 2020, Item #5Community Center AV Schematic __ IT Room in Office Block _____ _ RUI RU2 RUl I BLANK RU4 RUS RU6 RU? RUB RU9 EQUIPMENT RACK ELEVATION RU IO CATRX I CATRX } RUl 1 CAT RX I CAT RX More space RU12 CATTX I CATTX consolidation? RU 1l CATTX I CATTX RUl4 LISTENLW-200P-08 RUIS LT-800-72 RUl6 I BLANK RUil QSCCX-Q4K8 RUIS 1--------------i RU19 QSCCX-Q4K8 RU20 .__ _________ ____. --,;-021<4 -~ MULTIPURPOSE r-------------------~ ZONE4 IRfGHTJ • Equipment Rack (Storage Closet Between Auditorium and Multipurpose Room, 7ft off ground). r-----------------------------~ I CATEXTENDERW/USB?fOfCYNAP 1_ C~T~lCT_EN_~RW/USS?rorCYNAP ~~)\ ~--------...__-----,--------l.-.. -,,,---~==~----, -rONPROL::::.UNl1 AD<6T EJ----g ~-zoru (BACK) ,_ ---------------- - - -------- -_ J MULTIPURPOSE ROOM ' I ~,-----,~ ,-•m,. ---1----;..___a-0 I ----I CATEXTENOER I ~ ~ ZONE3 !LEFT! ZONE-1 I (RIGHTI t ~ ---i____:::__J ·-------------------------------------------------------· --------------------------------~ DANCE STUDIO t' --- --- - - --- --- -- --- - -- -~-- - --- - - - --- - - --~ - - -'I .~ ~ .... 0 ·~ ------------------------------------------~ M October 20, 2020, Item #5(~ .• ~."'~':"' Community Center AV System RFP 21-007 \~J Addendum #2 ~!~'9~ Clarifications: • In addition to the RF ALS, there is an 8-channel wifi ALS system. The City wants to have 4 channels with stereo sound -the result is that every section of the Auditorum and Multipurpose room can have different stereo audio. This will also affect the design of touchscreen panels so that there are 4 ALS channels that can be selected/volume levels controlled instead of 2. • The City would like to increase the size of the projection screen for the Auditorum. o Approx. 220" diagonal, 192" wide, and 108" high. The approx. throw distance is between 9.5' to 10.5'. Power outlet will be placed at 9.5' from the projection screen/wall • The City will provide a UPS 2 RU for: 4 NV-32, Core ll0F; Network Switch; and CAT transmission equipment and audio equipment (excluding audio amplifers). • The City will provide qty 2 of 1 RU OFE Power Conditioners. This is updated in the attached schematic. Total of (8x2) 16 outlets. • Proposer should also include cable management for the rack. This will take up another lRU. See photo to the right. Questions: 1. Is there a pathway from the Dance Studio closet to the Auditorium/MP closet in order to simplify the connection of the audio equipment to the AV switch? a. Unfortunately, there is no direct path between those two locations. The Dance Studio closet equipment will have to be wired back to the IT Room and then; b. The City's Network Administrator will have to create the VLAN to isolate the AV network on the IT Room main switch. 2. What are the cable lengths for antenna distribution? a. The approximate length of cable can be estimated from the project plans. Please ensure the appropriate equipment is spec'd for the transmission and receiving of microphone and ALS receiver signals. 3. Should there be two Cynap and two Cox recievers? a. The assumption is that the Cynap and the Cox will not be used very often in comparison to the HDMI inputs. With this set up, you can only have one TV channel sent to one (or up to 4) rooms if viewing same cable TV channel simultaneously (same with any other source) when the Advanced controls are used. 4. Are there any prevailing wage requirements for this project? a. Yes the project is prevailing wage. 5. Would the City of Poway be able to provide bidders with construction drawings with floor plans, RCP's, etc. for this buildout? a. A more complete set of plans is attached to this Addendum #2. 6. What are the warranty requirements? 32of49 a. 1-year full-service warranty to cover problems in operation, coding, and products. 1 year count starts after signing off on the project as complete. b. Include email, phone, chat and remote support c. Facilitiate Manufacturer's Warranty Repair or Replacements d. Provide loaner equipment if possible e. Onsite labor by next business day. f. Please provide optional annual pricing for support after year 1, as well as single support calls and cost for weekend or after hours support. (Community Park is open nights and weekends.) October 20, 2020, Item #5City of Poway Community Center AV System RFP 21-007 7. Will there ever be a scenario where all four spaces of the Auditorium and Multipurpose Room will be used independently simultaneously? If so, should three additional ALS transmitters be added to the system to allow for use of the system in each space? a. The RF transmitter can be used for any area bsing the touchpanel, select the correct audio to send over the RF system. The RF recievers will be stored at Community Park front desk. b. In the case where more than one area needs ALS service, staff will employ the Wifi ALS system and route the correct audio. 8. There are only two touch panels defined in the scope. With all spaces divided, there are four spaces in total. Should two more touch panels be added to the system? a. The spaces will almost always be used as a complete room and not a split room. When the room is split, it is assumed that staff will assist in the splitting of the room and setting up of the system using the Advanced touchscreen settings (only available to staff with the code). 9. Are substitutions of equipment permitted? a. There are only limited areas where the City is allowing subsitutions: i. CAT extenders allows 2 manufacturers ii. Projector screens have several manufacturers listed iii. However, control, video, audio systems are specific because we wanted to minimize the number of separate systems to integrate. The QSYS system allows for some streamlining. The speakers had desired clarity. Projection had performance that was good. iv. Antenna distribution and amplification 10. If substitutions are permitted, is Crestron an acceptable manufacturer for control and AV switching and distribution? a. Crestron will not be accepted as a substitution for the control and AV switching. 11. Is a network infrastructure provided by others for the wireless presentation solution or is the AV contractor expected to provide a wireless network? a. The City will have wireless infrastructure that is expected to be used for guests, and City equipment. It is anticipated that the guest network can be used for this purpose. 12. Is a network infrastructure provided by others for the Wi-Fi portion of the ALS system or is the AV contractor expected to provide a wireless network? a. The City will have wireless infrastructure that is expected to be used for guests, and City equipment. It is anticipated that the guest network can be used for this purpose. 13. The RFP mentions a Wo/fvision Cynap Pure Pro for wireless presenting, however, only a Wolfvision Cynap Pure is defined in the Partial Parts List. Please advise on discrepancy. a. One (1) Cynap Pure Pro will be used for wireless presentations. 14. The Partial Parts List defines {1} Wolfvision Cynap Pure. Will there be a need for (4) total units to allow wireless presenting simultaneously in each space while all spaces are divided? a. There will be only one Cynap unit in the parts list, as the wired methods of connection will be more regularly used. 15. A QSC KS112 is defined in the Partial Parts List, however, it is not mentioned in the rest of the RFP. Please advise on discrepancy. 33 of 49 a. The KS112 is a subwoofer that will be employed and connected to the system as neededby usinconnecting to the XLR out ports on the walls of each room. These subwoofers can be used in any of the three rooms. Page 2 of 2 October 20, 2020, Item #5Community Center AV Schematic v2 RUl RU2 RU3 RU4 RUS RU6 RU7 RUB RU9 __ IT Room in Office Block _____ _ ·---------------------... EQUIPMENT RACK ELEVATION QSCCX-Q4K8 QSCCX-Q4K8 OFE Power Conditioner COX CableTvTuner CynapPure Core 110F Cable Management OFE Network Switch RU10 I NV-32#1 I NV-32#2 I RU11 • NV-32#3 • NV-32#4 • RU12 UPS RU13 t--------------i RU14 OFE Power Conditioner RUIS CATRX I CAT RX } RU16 CAT RX I CAT RX More space RU17 CATTX I CATTX consolidation? RU 18 CATTX I CATTX RU19 ULXD4Q RU20 LISTEN LW-200P-08 RU21 LT-800-72 ; - -C;-O;K◄-- ----MULTIPURPO~ ~-------------------~ ZONE<l (RIGl·iTI Equipment Rack (Storage Closet Between Auditorium and Multipurpose Room, 7ft off ground) r-------------------------------------------------------~ I CATEXTENDERW/USB?fOfCYNAP I CATEXTENOERW/USB?forCYNA.P CATEXTE~_B_ ZONEl l'nUJC"-IIVN><.tCCl'I (FRONT) ~ l_____:'._'.'.' nCX-0BK8!2 AD<6T AD<6T L-------'---.--,.__---"----:-----~M I ,_ --------------- - - - - ------- -_ J MULTIPURPOSE ROOM • I I CATEXTENOER I ~ ~ ZONE3 ILErTl ... -~ -t ZONE◄ i I (RIGH11 I ~ ~ I I I ________________________________ _! ~-----------¥--~w-•-••-•--•-------------------------•*-~~ DANCE STUDIO f' - - - -· --- - - -- -------- --- ---- -------- ---- - --- -.. t, __________________________________________ ,. °' -.:!' .... 0 -.:!' M ---------------76-'&----------------------------7676-'&---------- - --------$8',725,800((7,1*5220287'2253$7,26725$*(:20(1 65(6752200(1 65(675220.,7&+(16725$*(%,1*26725$*(0((7,1*5220(/(&+$//.3:3:+/$81'5< $)):3:37<33333333333&1*33&1*33333&1**+,-./0123468.$,5&857$,1.&1*,&(0$&+,1(..5$1*(5($&+,1+22'.&21752/3$1(/.&1*55+27&$%,1(7.:$6+(5.+22'(;08$.&1*.5...&1*..3303&3///3333//.&1*.&1*.&1*.&1*7<3:+.,&(0$&+,1(//6)'.&1*:$308/7,385326(5220%0(1 65(675220%:20(1 65(675220%.,7&+(16725$*(287'2253$7,2(/(&%,1*26725$*(0((7,1*5220$8',725,800((7,1*5220.36725$*(%-$1/$81'5< $)) $))33*+,-./01234687<33&1*330&37<37<3:3 $)):3:30///:+$,5&857$,15$1*(5($&+,1+22'&21752/3$1(/55+27&$%,1(7:$6+(5+22'(;08$:+,&(0$&+,1(//*(1(5$/127(6$%(/(&75,&$/&2175$&725723529,'(',0(16,21('6+23'5$:,1*62)$//(/(&75,&$/52206$1'3$1(//2&$7,21635,2572528*+,1&225',1$7($//:$//02817('(/(&75,&$/'(9,&(/2&$7,216:,7+$'$5(48,5(0(1763529,'(&38//675,1*:,7+($&+7(/(3+21($1''$7$'523/2&$7,21&225',1$7($'',7,21$/5(48,5(0(176:,7+7(/(&20081,&$7,216&2175$&72535,2572528*+,1&,)&,5&8,7,1*)2532:(5,61276+2:1217+(%,'$/73/$17+$1,7,6,'(17,&$/7+($'-$&(173/$16((7+,66+((7'$//:($7+(53522)5(&(37$&/(66+$//%((48,33(':,7+/2&.$%/(&29(5).#64+%'%.'4''4')+56'4'&241('55+10#.'0)+0 56#6'1(%#.+(140+##06100#6*#0510 'ZR0Q'(/(1&2168/7,1*&+(6$3($.('5,9(67(6$1',(*2&$:::(/(1&2168/7,1*&20.(<3/$1'HVFULSWLRQ'DWH3URMHFW1XPEHU'UDZQ%\&KHFNHG%\6KHHW7LWOH$SSURYHG%\6KHHW1XPEHUZZZMHIINDW]DUFKLWHFWXUHFRP6&+(0$7,&'(6,*1'(6,*1'(9(/230(17&216758&7,21'2&80(176&216758&7,21'2&80(176%8,/',1*'(3768%0,77$/%8,/',1*'(3$570(175(68%0,77$/'(/&(552%28/(9$5'_6$1',(*2&$_3URMHFW%,'6(75(%,'6(732:(5)/2253/$1608/7,385326(%/2&.(0,&.(<&$)$*1$&20081,7<&(17(5&,7<2)32:$<&LYLF&HQWHU'U3RZD\&$$1$1.66&$/(  (32:(53/$1 08/7,385326(%/2&.6&$/(  (%,'$/7 32:(53/$1 08/7,385326(%/2&.6+((7.(<127(6.H\9DOXH.H\QRWH7H[W 3529,'(932:(5723$57,7,216(1625$1'&211(&7,2172/,*+7,1*&21752/6<67(0 3529,'(-%2;)25&211(&7,21723$57,7,2102725 &211(&7,2172(/(&75,&+$1''5<(5 35,0$5<'$</,*+7=21(3(5&(&7,7/( 3529,'(-%2;)2532:(5&211(&7,2172&(,/,1*352-(&725 $//(;7(5,255(&(37$&/(66+$//+$9()/$7(;3$1'$%/(&29(57<0$&0/*25(48$/ 3529,'(6:,7&+)25352-(&7256&5((1 $//&,5&8,7,1*,1$5($2876,'(2)%,'$/76+2:121$'-$&(17'5$:,1*7+,66+((7 3529,'(-%2;&211(&7,21)2568%$/$503$1(/&225',1$7('(;$&7/2&$7,21:,7+6(&85,7<&2175$&72535,2572528*+,1 3529,'(528*+,1)25$9&21752/6&5(6752125(48$/&225',1$7(5(48,5(0(176$1'(;$&7/2&$7,21:,7+$9&2175$&72535,2572528*+,1 2)2,$95$&. 3529,'(/$%(/6$<,1*3$21'(',&$7(':($7+(53522)5(&(37$&/( 3529,'(&(,/,1*02817('5(&(37$&/()25 :,), +276327&225',1$7((;$&7/2&$7,21:,7+$5&+,7(&735,2572528*+,1 3529,'('225&217$&725,1-$0)2532:(5(':$//&217$&7256+$//3529,'($129(55,'(2)/,*+7,1*&21752/662%27+522066+$//$&7$621(5220 3529,'(6:,7&+)2552//83:,1'2:6&225',1$7((;$&7/2&$7,21:,7+2:1(5$1'$5&+,7(&735,2572528*+,1 3529,'(-%2;)2532:(5&211(&7,217252//836&5((16&225',1$7((;$&7/2&$7,21:,7+$5&+,7(&735,2572528*+,1 3529,'(-%2;)2572,/(7)/86+&211(&7,21&225',1$7((;$&7/2&$7,21:,7+$5&+,7(&7635,2572528*+,11/3----*-3-2E2.3FOR CONSTRUCTION11/14/1912/11/1935 of 49October 20, 2020, Item #5l) l) I I I I I i9 ~ © .,, ' ( J ~ o-G ~ 0, e-V, -~ .,, □ ± I ~ ~ D ,~s • > I . ffkatz1®.~ JKAHcHITECTURE J ------79 ---------(3(/(&0((7,1*&/$6652206725$*('$1&(678',20((7,1*&/$665220(9(17&2857<$5'38%/,&:25.6:25.$5($:20(1 65(6752200(1 65(675220-$16725$*(&(17(5&2857<$5'0((7,1*&/$6652200((7,1*&/$6652206725$*(6725$*(6725$*(:3:3*'6725$*(6725$*(6725$*(6725$*(6725$*(6725$*(6725$*(6725$*(:+:3:3:3:3:35(6752203&1*3&1*3&1*3&1*33&1*3&1*3333&1*0*+,-./012346573333&1*3$))3&1*,167$+27:+3&1*3&1*/////////333336)'6)'6)'3&1*&33&1*0((7,1*&/$665220%6725$*(%6725$*(%6725$*(%6725$*(%3&1*3&1*34657*(1(5$/127(6$%(/(&75,&$/&2175$&725723529,'(',0(16,21('6+23'5$:,1*62)$//(/(&75,&$/52206$1'3$1(//2&$7,21635,2572528*+,1&225',1$7($//:$//02817('(/(&75,&$/'(9,&(/2&$7,216:,7+$'$5(48,5(0(1763529,'(&38//675,1*:,7+($&+7(/(3+21($1''$7$'523/2&$7,21&225',1$7($'',7,21$/5(48,5(0(176:,7+7(/(&20081,&$7,216&2175$&72535,2572528*+,1&,)&,5&8,7,1*)2532:(5,61276+2:1217+(%,'$/73/$17+$1,7,6,'(17,&$/7+($'-$&(173/$16((7+,66+((7'$//:($7+(53522)5(&(37$&/(66+$//%((48,33(':,7+/2&.$%/(&29(5).#64+%'%.'4''4')+56'4'&241('55+10#.'0)+0 56#6'1(%#.+(140+##06100#6*#0510 'ZR0Q'(/(1&2168/7,1*&+(6$3($.('5,9(67(6$1',(*2&$:::(/(1&2168/7,1*&20.(<3/$1'HVFULSWLRQ'DWH3URMHFW1XPEHU'UDZQ%\&KHFNHG%\6KHHW7LWOH$SSURYHG%\6KHHW1XPEHUZZZMHIINDW]DUFKLWHFWXUHFRP6&+(0$7,&'(6,*1'(6,*1'(9(/230(17&216758&7,21'2&80(176&216758&7,21'2&80(176%8,/',1*'(3768%0,77$/%8,/',1*'(3$570(175(68%0,77$/'(/&(552%28/(9$5'_6$1',(*2&$_3URMHFW%,'6(75(%,'6(732:(5)/2253/$1&/$665220%/2&.(0,&.(<&$)$*1$&20081,7<&(17(5&,7<2)32:$<&LYLF&HQWHU'U3RZD\&$$1$1.66&$/(  (32:(53/$1 &/$665220%/2&.6&$/(  (%,'$/7 32:(53/$1 &/$665220%/2&.6+((7.(<127(6.H\9DOXH.H\QRWH7H[W &211(&7,2172(/(&75,&+$1''5<(5 3529,'('$7$32:(55(&(37$&/(6$%29(&(,/,1*7,/(6)256(&85(')$&,/,7<:,), 3529,'(-%2;&211(&7,21)2568%$/$503$1(/&225',1$7('(;$&7/2&$7,21:,7+6(&85,7<&2175$&72535,2572528*+,1 2)2,$95$&. 3529,'(/$%(/6$<,1*3$21'(',&$7(':($7+(53522)5(&(37$&/(FOR CONSTRUCTION11/14/1912/11/1936 of 49October 20, 2020, Item #5~aj ~ a ~ T $ ( f ~~.) ;" f l'i'& u • 9 ) ) l , T ~ f f k a t KA~~CHITECTUR • > %$'(*+,-./012346857&(((6725$*(,7(/(&7)263),%(5127(6  $8',29,68$/  &$0(5$  ),5($/$50  ,7    6(1,25,7  &(17(5,7  $/$50),5(  $9  $8',29,68$/  ),5($/$50  &21'8,7,7  ),5($/$50.#64+%'%.'4''4')+56'4'&241('55+10#.'0)+0 56#6'1(%#.+(140+##06100#6*#0510 'ZR0Q'(/(1&2168/7,1*&+(6$3($.('5,9(67(6$1',(*2&$:::(/(1&2168/7,1*&20.(<3/$1'HVFULSWLRQ'DWH3URMHFW1XPEHU'UDZQ%\&KHFNHG%\6KHHW7LWOH$SSURYHG%\6KHHW1XPEHUZZZMHIINDW]DUFKLWHFWXUHFRP6&+(0$7,&'(6,*1'(6,*1'(9(/230(17&216758&7,21'2&80(176&216758&7,21'2&80(176%8,/',1*'(3768%0,77$/%8,/',1*'(3$570(175(68%0,77$/'(/&(552%28/(9$5'_6$1',(*2&$_3URMHFW%,'6(75(%,'6(76(&85,7<3/$129(5$//(0,&.(<&$)$*1$&20081,7<&(17(5&,7<2)32:$<&LYLF&HQWHU'U3RZD\&$$1$1.66&$/(  (6(&85,7<3/$1 29(5$//FOR CONSTRUCTION11/14/1912/11/1937 of 49October 20, 2020, Item #5r i I --'------~---' I I I I I ------, I L ~ J I I I I I l I 1 I I I I I I _J . f f k a t z JKAHcHITECTURE 1122BBD4566778911111212FFGGJKLOPQTTAAIMHUREECOCCUPANCY LEGENDAB0EN 65E675OO0B211:O0EN 65E675OO0B212OU7DOO5PA7,O0EN 65E675OO01:O0EN 65E675OO02E9EN7COU57YA5D1 SF67O5AGE17,7112ELEC7.111LO%%Y11CEN7E5COU57YA5D67O5AGE167O5AGE1267O5AGE1167O5AGE167O5AGE467O5AGE567O5AGE667O5AGE7PLU0%,NGC+A6E67O5AGEB2567O5AGEB2667O5AGEB2767O5AGEB2867O5AGE2267O5AGE2167O5AGE1967O5AGE2ELEC15PLU0%,NGC+A6EELEC29-ANEN75ANCEPA7,O-AN28+ALL26ELEC115),5E 5,6E5116LAUND5Y275E675OO029PA7,O161 SF1126UPE59,6O5B6 SF151467O5AGE:O5.5OO0B614 SF1617LOUNGEB158 SF19126UPE59,6O5B66 SF111467O5AGE:O5.5OO0B268 SF67O5AGE11165 SF114126EN,O56E59,CE6B2472 SF2215165AUD,7O5,U00EE7,NG 5OO0A685 SF2524.,7C+ENB28 SF67O5AGE2124 SF%,NGO67O5AGE24759 SF215510EE7,NG CLA665OO0A111 SF1815680EE7,NG CLA665OO0A756 SF815510EE7,NG CLA665OO0A768 SF915510EE7,NG CLA665OO0A116 SF141578DANCE 67UD,OA528 SF1816C,7Y 67A))B156 SF17125ECEP7,ONB154 SF12125ECEP7,ONB51 SF14166EN,O5 67A))B45 SF1615PU%L,C :O5.6:O5. A5EAB215 SF2115140EE7,NG 5OO0A76 SFB2415510EE7,NG CLA665OO0A2941 SFB214151980UL7,PU5PO6E5OO0A415 SF67O5AGEB21OL 14 PERSONS28 E;IT :D REQ84 E;IT :D PRO9OL 55 PERSONS11 E;IT :D REQ42 E;IT :D PRO9OL  PERSONS6 E;IT :D REQ72 E;IT :D PRO9OL 4 PERSONS8 E;IT :D REQ42 E;IT :D PRO9OL 55 PERSONS11 E;IT :D REQ46 E;IT :D PRO9OL 55 PERSONS11 E;IT :D REQ84 E;IT :D PRO9MAIN E;IT OL 154 PERSONS1 E;IT :D REQ84 E;IT :D PRO9OL 7 PERSONS146 E;IT :D REQ84 E;IT :D PRO9OL 7 PERSONS14 E;IT :D REQ42 E;IT :D PRO9OL 75 PERSONS15 E;IT :D REQ72 E;IT :D PRO9OL 72 PERSONS144 E;IT :D REQ72 E;IT :D PRO9OL 6 PERSONS12 E;IT :D REQ48 E;IT :D PRO9OL 26 PERSONS52 E;IT :D REQ42 E;IT :D PRO9OL 4 PERSONS68 E;IT :D REQ42 E;IT :D PRO9OL 25 PERSONS5 E;IT :D REQ42 E;IT :D PRO9OL 4 PERSONS68 E;IT :D REQ42 E;IT :D PRO9OL 91 PERSONS182 E;IT :D REQ48 E;IT :D PRO9OL 9 PERSONS78 E;IT :D REQ42 E;IT :D PRO9OL 25 PERSONS5 E;IT :D REQ42 E;IT :D PRO9OL 9 PERSONS78 E;IT :D REQ42 E;IT :D PRO9OL 26 PERSONS52 E;IT :D REQ42 E;IT :D PRO9OL 26 PERSONS52 E;IT :D REQ42 E;IT :D PRO9OL 5 PERSONS1 E;IT :D REQ42 E;IT :D PRO9OL 4 PERSONS8 E;IT :D REQ42 E;IT :D PRO9OL 4 PERSONS8 E;IT :D REQ42 E;IT :D PRO9OL 25 PERSONS5 E;IT :D REQ42 E;IT :D PRO9OL 66 PERSONS12 E;IT :D REQ84 E;IT :D PRO9OL 66 PERSONS12 E;IT :D REQ84 E;IT :D PRO9OL 66 PERSONS12 E;IT :D REQ84 E;IT :D PRO9PHPHPHPHPHPHPHPHPHPHPHPHPHPHPHPHPHPHPHPHPHPHPHPHPHPHPHOL 5 PERSONS1 E;IT :D REQ42 E;IT :D PRO9PHPHPHAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA ABBBBBAAAABEBEBBBBBBCCBBE BEBBBDBAABAABAAAABAABAABABFFFFEEEFBBBEEAFEFEFEFEFEFEFEFEFEFE FE FEFEFEECEG2GGG2G15FT SEPARATION REQ 51FT SEPARATION PRO9 455FT SEPARATION REQ85FT SEPARATION PRO9FT SEPARATION REQ8FT SEPARATION PRO961FT SEPARATION REQ 1FT SEPARATION PRO9 2FT SEPARAT ION R EQ 1FT SEPAR ATI O N PRO9 24FT SEPARATION REQ4FT SEPARATION PRO925FT SEPARATIO N REQ 4FT SEPARAT ION PRO92FT SEPARATION REQ1FT SEPARATION PRO92FT SEPARATION R EQ 1FT S EPAR ATI ON PRO9 2FT SEPARATION REQ1FT SEPARATION PRO9445FT SEPARATION REQ82FT SEPARATION PRO9HHHHHHHHHH076117PHPHPATH OF TRA9ELE;IT SIGN SEE ELECTRICAL DRA:INGSPANIC HARD:ARE SEE DOOR SCHEDULEPHROOM OCC CLASSIFICATIONNET SQ FTOCC LOAD FACTOROCCUPANTS[[[[[[[[[[[[FIRE E;TINGUISHERFE[[[2[4 STUD :ALL2[6 STUD :ALL2[4 STUD :ALL 1 HOUR RATED2[6 STUD :ALL 1 HOUR RATED1 ROOMS LISTED :ITH NO OCCUPANT LOADS ARE CONSIDERED ACCESSOR< USES2 GRADE LE9EL AREAS DESIGNATED AS E;IT DISCHARGE COMPONENTS FOR BUILDING SHALL BE PERMANENTL< MAINTAINED SUCH AREAS SHALL NOT BE DE9ELOPED OR OTHER:ISE ALTERED IN THEIR CAPACIT< TO PRO9IDE CONTINUOUS UNOBSTRUCTED AND UNDIMINISHED MEANS OF EGRESS FOR THE BUILDING OCCUPANT IF SUCH AREAS ARE SOLD INDEPENDENT OF THE BUILDING THE< SER9E AN E;IT DISCHARGE COMPL<ING :ITH THE REQUIREMENTS OF SECTION 16 SHALL BE PRO9IDED FOR THE BUILDING  EGRESS DOORS SHALL BE READIL< OPERABLE FROM THE EGRESS SIDE :ITHOUT THE USE OF A KE< OR SPECIAL KNO:LEDGE OR EFFORT 4 MA;IMUM E;IT ACCESS DISTANCE SHALL BE NO FURTHER THAN 25 FT AS SHO:N HEREIN E;IT ACCESS DISTANCE DOES NOT E;CEED 12FT5 ACCESSIBLE ROUTES REQUIRED SHALL COMPL< :ITH EACH OF THE FOLLO:INGCOINCIDE :ITH OR BE LOCATED IN THE SAME AREA AS GENERAL CIRCULATION PATHSLOCATED :ITHIN BUILDING INTERIOR :HERE GENERAL CIRCULATION PATHS ARE INTERIORNOT PASS THROUGH KITCHENS STORAGE ROOMS RESTROOMS CLOSETS OR SIMILAR SPACES UNLESS SER9ING THOSE SPACES6ALL E;TERIOR GATES SHALL INCLUDE SIGNAGE STATING THAT GATES ARE TO BE LEFT OPEN AND UNLOCKED DURING NORMAL OPERATING HOURSAROOM SIGN SEE DETAIL A1/A71BTACTILE E;IT SIGN SEE DETAIL A/A71 CE;IT ROUTE SIGN SEE DETAIL A/71 DE;IT STAIR DO:N SEE DETAIL A1/A71 EMA; OCCUPANC< SIGNAGE SEE DETAIL B1/A71 F ASSISTI9E LISTENING SIGN SEE DETAIL D1/T6G1 ACCESSIBLE SINGLEUSER RESTROOM SIGN SEE DETAIL D1/A71G2 ACCESSIBLE :OMEN S RESTROOM SIGN SEE DETAIL D1/A71GACCESSIBLE MEN S RESTROOM SIGN SEE DETAIL D1/A71 HE9ACUATION SIGN SEE DETAIL B1/A714+)1+,8'/8+4°,+':9:2,)'5/2,+0)5'/48':@:94+)?*+)'8:./DHVFULSWLRQ DDWH PURMHFW NXPEHUDUDZQ B\CKHFNHG B\SKHHW TLWOHASSURYHG B\SKHHW NXPEHUZZZMHIINDW]DUFKLWHFWXUHFRPSCHEMATICDESIGN6/28/181 DESIGNDE9ELOPMENT5CONSTRUCTIONDOCUMENTS95CONSTRUCTIONDOCUMENTS8/2/181/22/1812/21/18BUILDING DEPTSUBMITTAL2/15/19BUILDING DEPTRESUBMITTAL4/17/19BID SET5/28/19REBID SET8/26/19'(/&(552%28/(9$5'_6$1',(*2&$_PURMHFW BID ALT EGRESS ANDSIGNAGE PLAN1842A2MICKE< CAFAGNACOMMUNIT< CENTERCIT< OF PO:A<194 CLYLF CHQWHU DUPRZD\ CA 9264CMJKMMSCALE/2 1 A2D1BID ALT EGRESS PLAN O9ERALL5OO0NU0%E5DE6C5,P7,ON6.). NE7 LOAD)AC7O5OCCUP CLA6611LOBB<67 SF 17B12 RECEPTION 154 SF 12B1SUPER9ISOR 161 SF 12B14SENIOR STAFF51 SF 16B15STORAGE:ORKROOM6 SF 14B16 LOUNGE 614 SF 17B17 RECEPTION 156 SF 12B18CIT< STAFF 528 SF 16B19SUPER9ISOR 158 SF 12B11STORAGE:ORKROOM66 SF 14B111ELECT1 SFB112IT54 SFB11STORAGE 268 SF1B114 SENIOR SER9ICES 165 SF 12B115ELEC 46 SFB116 FIRE RISER 22 SFB117MTS8 SF21MEETING ROOM215 SF 15 14A22 AUDITORIUMMEETING ROOM2472 SF 15 165 A2STORAGE 28 SF1A24 BINGO STORAGE 124 SF1A25 KITCHEN 685 SF 24B26HALL555 SFA27LAUNDR<17 SFA28JAN 22 SFA29ELEC14 SFA1MEN S RESTROOM95 SFA2:OMEN SRESTROOM4 SFAJAN SFA4STORAGE18 SFA5STORAGE17 SFA6STORAGE56 SFA7STORAGE57 SFA8 MEETING /CLASSROOM756 SF 15 51 A9 MEETING /CLASSROOM768 SF 15 52 A1STORAGE 17 SFA11 STORAGE 17 SFA12 STORAGE 52 SFA1STORAGE 5 SFA14DANCE STUDIO 116 SF 15 78 A15ELEC 12 SF16 PUBLIC :ORKS:ORK AREA45 SF 15B17 STORAGE 1 SFA18 MEETING /CLASSROOM111 SF 15 68 A19 STORAGE 17 SFA2STORAGE 17 SFA21 STORAGE 52 SFA22 STORAGE 52 SFA2MEETING /CLASSROOM759 SF 15 51 A29 RESTROOM 62 SFAB211 MEN S RESTROOM77 SFAB212:OMEN SRESTROOM77 SFAB21STORAGE 415 SFAB214 MULTIPURPOSEROOM2941 SF 15 197 AB24 MEETING /CLASSROOM76 SF 15 51 AB25 STORAGE 17 SFAB26 STORAGE 18 SFAB27 STORAGE 54 SFAB28 STORAGE 54 SFAGUDQG WRWDO2192 SF911EG5E66 LEGEND:ALL LEGENDEG5E66 NO7E66,GNAGE LEGENDTOTAL AREA NSF 2192 SFCORE AREA 6988 SFTOTAL AREA GSF 28911 SF8 4 16 FOR CONSTRUCTION11/14/1912/11/1938 of 49October 20, 2020, Item #5) mm j IG 0 0 0 0 0 0 0 '-..=---=;;;.= -r ~. Llf _g ·1 mm . :-~ D .. ~ 8 ::~ I ~ ~ i:~ i_ I C ~ ., ' I~ r:: 1h 0 mm •~ Ln ~• n• "=-====a(l::''N~;f-ce====="'===~~ .,--=--~ ◄···= f'° = 0 0 0 0 0 0 ····► • I ~ ,. ·i~ : ..... 4~ 00 0 0 " + 0 0 0 0 0 0 0 0 -'.) 0 0 0 0 0 0 0 H-tt-+---t-t-+-t-tt-tt-+++-+t-t-tt-+-+++-+-++++-+---t-tt-+-+-tt-tt-r-tt-tt+++++-++++-+----t-t--+-ti ~ H-tt-+---t-t-+-t-tt-tt+++-+t-t-tt-++++-+-++++-+---t-tt-+-+-tt-tt-f---+++++++++-++++-+----t-t--+-ti ~ H-tt-+---t-t-+-t-tt-tt-+++-+t-t-tt-+-+++-+-++++-+---t-tt-+-+-tt-tt-r-tt-tt+++++-++++-+----t-t--+-ti ~ H-tt-+---t-t-+-t-tt-tt+++-+t-t-tt-+-+++-+-++++-+---t-tt-+-+-tt-tt-f---+++++++++-++++-+----t-t--+-ti ~ H-tt-+---t-t-+-t-tt-tt-+++-+t-t-tt-+-+++-+-++++-+---t-tt-+-+-tt-tt-f---+++++++++-++++-+----t-t--+-ti ~ ~ 112266GGJJKLOPQQTTI11 22 111 22 111 22 111 22 111 21 RO6   RO6 5 6RO6 15 5RO6   RO6 6 17 4RO6  RO6 2 17 RO6 2 2 1RO6 7 7 RO6 5 RO6 7 1 6RO6   RO6   RO6 5 6RO6 5 6RO6   RO6 6 57 7RO6   RO6   110EE7,NGCLA665OO0267O5AGE2167O5AGE2267O5AGE170EE7,NGCLA665OO018:O0EN 65E675OO020EN 65E675OO01-AN67O5AGE667O5AGE767O5AGE167O5AGE12E9EN7COU57YA5DDANCE 67UD,O140EE7,NGCLA665OO090EE7,NGCLA665OO08PU%L,C :O5.6:O5. A5EA16ELEC.1567O5AGE1167O5AGE167O5AGE467O5AGE567O5AGE1967O5AGE218 616 118 67 2 19 5 76 27 9 8 48 67 /D1A22 7 15 4 7 1 1 415 15 1124 716 4 11 1 24 51  15 7RO6 8 RO6 8 8 11RO6  118 127 87 418 51 8RO6 1 92 4 12 54 2 5 84 6 26 1126 66 81 41 7 51 78 51 9 118 14 712 19 9 75 7RO6 8 RO6 8 8 11RO6 12 6RO6 7 29 4 627 9 5 6 55 6 11 41 7 51 98 71 714 14 58 2RO6 91 9RO6 8 29 9 71 68 61 65E675OO0296 64 EQ4 EQ4 6 61 2 52 6;;;;;;;;66QTR 10EE7,NG CLA665OO0B247 RO6  RO6  RO6 1 17 RO6 7 67O5AGEB2767O5AGEB2867O5AGEB2667O5AGEB252 12 16 4  6 7 4 51 4 71 41 68 11 618 119ERIF< ALL ROUGH OPENING SI=ES PRIOR TO FRAMING2SEE ENLARGED PLANS FOR ADDITIONAL INFORMATION.EY PLAN+)1+,8'/8+4°,+':9:2,)'5/2,+0)5'/48':@:94+)?*+)'8:./DHVFULSWLRQ DDWH PURMHFW NXPEHUDUDZQ B\CKHFNHG B\SKHHW TLWOHASSURYHG B\SKHHW NXPEHUZZZMHIINDW]DUFKLWHFWXUHFRPSCHEMATICDESIGN6/28/181 DESIGNDE9ELOPMENT5CONSTRUCTIONDOCUMENTS95CONSTRUCTIONDOCUMENTS8/2/181/22/1812/21/18BUILDING DEPTSUBMITTAL2/15/19BUILDING DEPTRESUBMITTAL4/17/19BID SET5/28/19REBID SET8/26/19'(/&(552%28/(9$5'_6$1',(*2&$_PURMHFW DIMENSIONPLAN CLASSROOMBLOCK1842A27MICKE< CAFAGNACOMMUNIT< CENTERCIT< OF PO:A<194 CLYLF CHQWHU DUPRZD\ CA 9264CMJKMMSCALE1/8 1 A27D1DIMENSION PLAN CLASSROOM BLOCKSCALE1/8 1 A27C4BID ALT DIMENSION PLAN CLASSROOM BLOCKNO7E6MATCHLINESEE8 16 4 8 FOR CONSTRUCTION11/14/1912/11/1939 of 49October 20, 2020, Item #50 0 0 0 j : 0 I I I I I I -}<:c· mnJJ=t-tt~~;;s~_-rJ,• rr~i· =,,.r ~r d 1 ·· . C D ' ' , ' ) 0 I 00 ~ D I I -, -n _,_, I -, r: ! r-u D I I I I D I I I I 4 I I . 000 0 0 0000000&'&'&'&'&'&'&'&'&'&'&'&'&0BBD4456677899FFAA1 EN75ANCEPA7,OLO%%Y115ECEP7,ON126UPE59,6O5167O5AGE:O5.5OO0156EN,O5 67A))14%5EA. 5OO0166EN,O56E59,CE611467O5AGE11,7112ELEC7.11167O5AGE:O5.5OO011C,7Y 67A))185ECEP7,ON176UPE59,6O519EE/D1A29/D1A2112 12 6221 1 CT<P64ELEC115),5E 5,6E5116541 1 1 1 1 T<P947T<P64T<P64T<P64T<P6445999529529962291207611711  911  91 CONTRACTOR SHALL 9ERIF< DIMENSIONS AND LA<OUT OF ALL FI;TURES AND EQUIPMENT :ITH ARCHITECT PRIOR TO ROUGH IN REQUEST CLARIFICATION FOR AN< DIMENSIONS NOT SHO:N 2 PRO9IDE STAINLESS STEEL ACCESS PANELS AS REQUIRED FOR MECHANICAL EQUIPMENT REFERENCE MECHANICAL DRA:INGS  SEE ROOM FINISH SCHEDULE FOR CEILING HEIGHTS NOT SHO:N4 SUSPENDED CEILING SHALL COMPL< :ITH CBC 5 E;IT SIGNS SHALL BE READIL< 9ISIBLE FROM AN< DIRECTION OR APPROACH6 E;IT SIGNS SHALL BE LOCATED AS NECESSAR< TO CLEARL< INDICATE THE DIRECTION OF EGRESS TRA9EL NO ONE POINT SHOULD BE MORE THAN 1 FEET FROM THE NEAREST 9ISIBLE SIGN7 PRO9IDE BLOCKING FOR ALL CEILINGMOUNTED EQUIPMENT SEE STRUCTURAL DRA:INGS FOR BLOCKING SI=E AND ANCHORAGE REQUIREMENTS8 LOCATE ALL SMOKE DETECTORS SPEAKERS SPRINKLERS AND ALL OTHER CEILING MOUNTED MECHANICAL ELECTRICAL PLUMBING SECURIT< AND FIRE SPRINKLER ITEMS AT THE CENTER OF ACOUSTICAL CEILING PANELS UNLESS OTHER:ISE NOTED2 [2 RECESSED LIGHT FI;TURE2 [2 ACOUSTIC SUSPENDEDPANEL CEILINGG<PSUM BOARD CEILING PAINTCAN LIGHTOCCUPANC< SENSORE;IT SIGNT111 PAINT OR STAINOPEN TO STRUCTURE PAINT ENTIRET< OF E;POSED STRUCTURE DUCT:ORK CONDUITS AND PIPINGSTUCCO CEILING PAINTSUSPENDED LIGHT FI;TURE0RETURN REGISTERSUPPL< REGISTERSUSPENDED LIGHT FI;TUREE;HAUST AIR GRILLE2 [2 EMERGENC< LIGHT FI;TUREDA<LIGHT SENSORDOOR CONTACTROOFMOUNTED PHOTO CELL'&'63&PENDANT LIGHT FI;TURE.EY PLAN+)1+,8'/8+4°,+':9:2,)'5/2,+0)5'/48':@:94+)?*+)'8:./DHVFULSWLRQ DDWH PURMHFW NXPEHUDUDZQ B\CKHFNHG B\SKHHW TLWOHASSURYHG B\SKHHW NXPEHUZZZMHIINDW]DUFKLWHFWXUHFRPSCHEMATICDESIGN6/28/181 DESIGNDE9ELOPMENT5CONSTRUCTIONDOCUMENTS95CONSTRUCTIONDOCUMENTS8/2/181/22/1812/21/18BUILDING DEPTSUBMITTAL2/15/19BUILDING DEPTRESUBMITTAL4/17/19BID SET5/28/19REBID SET8/26/19'(/&(552%28/(9$5'_6$1',(*2&$_PURMHFW REFLECTEDCEILING PLAN OFFICE BLOCK1842A28MICKE< CAFAGNACOMMUNIT< CENTERCIT< OF PO:A<194 CLYLF CHQWHU DUPRZD\ CA 9264CMJKMMSCALE1/8 1 A28D1REFLECTED CEILING PLAN OFFICE BLOCKNO7E6MATCHLINESEEMATCHLINESEELEGENDCON675UC7,ON NO7E645ROOF ACCESS HATCH SEE D2/A7554ROOF ACCESS LADDER622 G<PSUM BOARD SOFFIT64STUCCO912 E;POSED PIPE SEE PLUMBING DRA:INGS947 LIGHT FI;TURE SEE ELECTRICAL DRA:INGS952 MECHANICAL EQUIPMENT SEE MECHANICAL DRA:INGS99ELECTRICAL EQUIPMENT SEE ELECTRICAL DRA:INGS8 16 4 8 FOR CONSTRUCTION11/14/1912/11/1940 of 49October 20, 2020, Item #5,0 0 0 0 0 I I I I I I 0 I 0 I I 0 I I I tIB D I I I I I I 0 [l!] D till 0 IIIJ ® [l!] DI] 0 llD 9Jii -0 ® rnP c::F 0 el 8i1 llD DI] IBJ DI] ~ IBJ llD '\J IBJ I DI] D IBJ IBJ D I Oil @) [i] I tEl 0 I llD IIIJ I om I IIIJ □ IBJ 0 I I IBJ Oil I DI] 0 I I I I I I I I 'o 0 0 0 0 ~ ff katz ~ JKA~~CHITECTURE w '6'6'6000009990000000000000'6'6'60000000000'&'&'&'&'&&'&'&'6'6'600000990000000099990000000000000'6'6'6000000000000'&'&'&'&'&&'&'&'&'&'&'&07711111212GGSSNMHAUD,7O5,U00EE7,NG 5OO0220EE7,NG 5OO02167O5AGE2%,NGO67O5AGE24.,7C+EN25+ALL26:O0EN 65E675OO02120EN 65E675OO021167O5AGE21ELEC29PLU0%,NGC+A6EOU7DOO5PA7,O1 8 8 1 -AN28/C4A21565LAUND5Y2762212 5477771T<P61812 8 45T<P912T<P912T<P912912912912T<P991484848A29D;;;;7711111212GGSSMHUU8 8 1 AUD,7O5,U00EE7,NG 5OO0220EE7,NG 5OO02167O5AGE2%,NGO67O5AGE24.,7C+EN25:O0EN 65E675OO0B2120EN 65E675OO0B2110UL7,PU5PO6E5OO0B214ELEC29PLU0%,NGC+A6EOU7DOO5PA7,O1 -AN28/D1A2867O5AGEB21LAUND5Y27+ALL267777T<P618T<P91248481 CONTRACTOR SHALL 9ERIF< DIMENSIONS AND LA<OUT OF ALL FI;TURES AND EQUIPMENT :ITH ARCHITECT PRIOR TO ROUGH IN REQUEST CLARIFICATION FOR AN< DIMENSIONS NOT SHO:N 2 PRO9IDE STAINLESS STEEL ACCESS PANELS AS REQUIRED FOR MECHANICAL EQUIPMENT REFERENCE MECHANICAL DRA:INGS  SEE ROOM FINISH SCHEDULE FOR CEILING HEIGHTS NOT SHO:N4 SUSPENDED CEILING SHALL COMPL< :ITH CBC 5 E;IT SIGNS SHALL BE READIL< 9ISIBLE FROM AN< DIRECTION OR APPROACH6 E;IT SIGNS SHALL BE LOCATED AS NECESSAR< TO CLEARL< INDICATE THE DIRECTION OF EGRESS TRA9EL NO ONE POINT SHOULD BE MORE THAN 1 FEET FROM THE NEAREST 9ISIBLE SIGN7 PRO9IDE BLOCKING FOR ALL CEILINGMOUNTED EQUIPMENT SEE STRUCTURAL DRA:INGS FOR BLOCKING SI=E AND ANCHORAGE REQUIREMENTS8 LOCATE ALL SMOKE DETECTORS SPEAKERS SPRINKLERS AND ALL OTHER CEILING MOUNTED MECHANICAL ELECTRICAL PLUMBING SECURIT< AND FIRE SPRINKLER ITEMS AT THE CENTER OF ACOUSTICAL CEILING PANELS UNLESS OTHER:ISE NOTED2 [2 RECESSED LIGHT FI;TURE2 [2 ACOUSTIC SUSPENDEDPANEL CEILINGG<PSUM BOARD CEILING PAINTCAN LIGHTOCCUPANC< SENSORE;IT SIGNT111 PAINT OR STAINOPEN TO STRUCTURE PAINT ENTIRET< OF E;POSED STRUCTURE DUCT:ORK CONDUITS AND PIPINGSTUCCO CEILING PAINTSUSPENDED LIGHT FI;TURE1 ; 4 RECESSED LIGHT FI;TURE04 [4 ACOUSTIC SUSPENDEDPANEL CEILING2 [2 EMERGENC< LIGHT FI;TUREDA<LIGHT SENSORDOOR CONTACTROOFMOUNTED PHOTO CELL'&'63&RETURN REGISTERSUPPL< REGISTERE;HAUST AIR GRILLEHALL:A< 9ACANC< SENSOR9.EY PLAN+)1+,8'/8+4°,+':9:2,)'5/2,+0)5'/48':@:94+)?*+)'8:./DHVFULSWLRQ DDWH PURMHFW NXPEHUDUDZQ B\CKHFNHG B\SKHHW TLWOHASSURYHG B\SKHHW NXPEHUZZZMHIINDW]DUFKLWHFWXUHFRPSCHEMATICDESIGN6/28/181 DESIGNDE9ELOPMENT5CONSTRUCTIONDOCUMENTS95CONSTRUCTIONDOCUMENTS8/2/181/22/1812/21/18BUILDING DEPTSUBMITTAL2/15/19BUILDING DEPTRESUBMITTAL4/17/19BID SET5/28/19REBID SET8/26/19'(/&(552%28/(9$5'_6$1',(*2&$_PURMHFW REFLECTEDCEILING PLAN MULTIPURPOSEBLOCK1842A29MICKE< CAFAGNACOMMUNIT< CENTERCIT< OF PO:A<194 CLYLF CHQWHU DUPRZD\ CA 9264CMJKMMSCALE1/8 1 A29D1REFLECTED CEILING PLAN MULTIPURPOSE BLOCKCON675UC7,ON NO7E645ROOF ACCESS HATCH SEE D2/A7548ATTIC ACCESS PANEL54ROOF ACCESS LADDER565 RANGE HOOD618 ACOUSTIC SUSPENDED PANEL CEILING SEE A711622 G<PSUM BOARD SOFFIT77CEILING MOUNTED PROJECTOR OFOI CONTRACTOR TO PRO9IDEBLOCKING AND COORDINATE ADDITIONAL REQUIREMENTS :ITH CIT<9ENDOR771:ALL MOUNTED PROJECTION SCREEN OFOI CONTRACTOR TOPRO9IDE BLOCKING AND COORDINATE ADDITIONAL REQUIREMENTS:ITH CIT< 9ENDOR912 E;POSED PIPE SEE PLUMBING DRA:INGS991 ROUND DIFFUSER SEE MECHANICAL DRA:INGSSCALE1/8 1 A29DBID ALT REFLECTED CEILING PLAN MULTIPURPOSE BLOCKMATCHLINESEEMATCHLINESEENO7E6LEGEND8 16 4 8 FOR CONSTRUCTION11/14/1912/11/1941 of 49October 20, 2020, Item #5Q 0 0 0 0 00 0 0 =11 0 [8l [8l [8l r I 'D D @ I 8'.W,.. .a° I ol 0 @ 0 ,@ 0 [f .-'-.....---,,-0 l ..,, 0 0 0 ~ @ @ ! -=' Q I I I I I I I I I I I I I I I I I I I I I I 00' 0 I I I I @ 7· i I I I l : I I I I I I I I I I I I I I I I • I I I I I I I I I I I I I I I I I I JI : I I I 00' D 0 0 0 D 0 0 f f k a t z JKA~~CHITECTURE 00000000000000000'6'6'6'6'6'&'&'&'&'&'&'&'&'&'&'&'&'&'&'&'&'&'&'&'&3&000'6'&'&'&'&'&1 CONTRACTOR SHALL 9ERIF< DIMENSIONS AND LA<OUT OF ALL FI;TURES AND EQUIPMENT :ITH ARCHITECT PRIOR TO ROUGH IN REQUEST CLARIFICATION FOR AN< DIMENSIONS NOT SHO:N 2 PRO9IDE STAINLESS STEEL ACCESS PANELS AS REQUIRED FOR MECHANICAL EQUIPMENT REFERENCE MECHANICAL DRA:INGS  SEE ROOM FINISH SCHEDULE FOR CEILING HEIGHTS NOT SHO:N4 SUSPENDED CEILING SHALL COMPL< :ITH CBC 5 E;IT SIGNS SHALL BE READIL< 9ISIBLE FROM AN< DIRECTION OR APPROACH6 E;IT SIGNS SHALL BE LOCATED AS NECESSAR< TO CLEARL< INDICATE THE DIRECTION OF EGRESS TRA9EL NO ONE POINT SHOULD BE MORE THAN 1 FEET FROM THE NEAREST 9ISIBLE SIGN7 PRO9IDE BLOCKING FOR ALL CEILINGMOUNTED EQUIPMENT SEE STRUCTURAL DRA:INGS FOR BLOCKING SI=E AND ANCHORAGE REQUIREMENTS8 LOCATE ALL SMOKE DETECTORS SPEAKERS SPRINKLERS AND ALL OTHER CEILING MOUNTED MECHANICAL ELECTRICAL PLUMBING SECURIT< AND FIRE SPRINKLER ITEMS AT THE CENTER OF ACOUSTICAL CEILING PANELS UNLESS OTHER:ISE NOTED11266GGJJKLOPQQTTI1 1 8 8 1 1 1 E9EN7COU57YA5DPU%L,C :O5.6:O5. A5EA16ELEC.15DANCE 67UD,O1467O5AGE1267O5AGE10EE7,NGCLA665OO090EE7,NGCLA665OO0867O5AGE767O5AGE6:O0EN 65E675OO020EN 65E675OO01-AN0EE7,NGCLA665OO020EE7,NGCLA665OO01867O5AGE1767O5AGE2167O5AGE2267O5AGE267O5AGE1967O5AGE567O5AGE467O5AGE167O5AGE11/D1A2812 1 8EQEQEQ5E675OO0298 7777177177661544554456464T<P912T<P912912PLU0%,NGC+A6E912T<P9129  9  484866PQQTTR1 0EE7,NG CLA665OO0B2467O5AGEB2767O5AGEB2867O5AGEB2667O5AGEB2512 649  2 [2 RECESSED LIGHT FI;TURE2 [2 ACOUSTIC SUSPENDEDPANEL CEILINGG<PSUM BOARD CEILING PAINTCAN LIGHTOCCUPANC< SENSORE;IT SIGNT111 PAINT OR STAINOPEN TO STRUCTURE PAINT ENTIRET< OF E;POSED STRUCTURE DUCT:ORK CONDUITS AND PIPINGSTUCCO CEILING PAINTSUSPENDED LIGHT FI;TURE0RETURN REGISTERSUPPL< REGISTERE;HAUST AIR GRILLE2 [2 EMERGENC< LIGHT FI;TUREDA<LIGHT SENSORDOOR CONTACTROOFMOUNTED PHOTO CELL'&'63&14 [ 14 ACCESS PANEL.EY PLAN+)1+,8'/8+4°,+':9:2,)'5/2,+0)5'/48':@:94+)?*+)'8:./DHVFULSWLRQ DDWH PURMHFW NXPEHUDUDZQ B\CKHFNHG B\SKHHW TLWOHASSURYHG B\SKHHW NXPEHUZZZMHIINDW]DUFKLWHFWXUHFRPSCHEMATICDESIGN6/28/181 DESIGNDE9ELOPMENT5CONSTRUCTIONDOCUMENTS95CONSTRUCTIONDOCUMENTS8/2/181/22/1812/21/18BUILDING DEPTSUBMITTAL2/15/19BUILDING DEPTRESUBMITTAL4/17/19BID SET5/28/19REBID SET8/26/19'(/&(552%28/(9$5'_6$1',(*2&$_PURMHFW REFLECTEDCEILING PLAN CLASSROOMBLOCK1842A21MICKE< CAFAGNACOMMUNIT< CENTERCIT< OF PO:A<194 CLYLF CHQWHU DUPRZD\ CA 9264CMJKMMCON675UC7,ON NO7E645ROOF ACCESS HATCH SEE D2/A7548ATTIC ACCESS PANEL54ROOF ACCESS LADDER64STUCCO661 STUCCO CONTROL JOINTS SEE B1/A7877CEILING MOUNTED PROJECTOR OFOI CONTRACTOR TO PRO9IDEBLOCKING AND COORDINATE ADDITIONAL REQUIREMENTS :ITH CIT<9ENDOR771:ALL MOUNTED PROJECTION SCREEN OFOI CONTRACTOR TOPRO9IDE BLOCKING AND COORDINATE ADDITIONAL REQUIREMENTS:ITH CIT< 9ENDOR912 E;POSED PIPE SEE PLUMBING DRA:INGSNO7E6SCALE1/8 1 A21D1REFLECTED CEILING PLAN CLASSROOM BLOCKMATCHLINESEESCALE1/8 1 A21C4BID ALT REFLECTED CEILING PLAN CLASSROOM BLOCKLEGEND8 16 4 8 FOR CONSTRUCTION11/14/1912/11/1942 of 49October 20, 2020, Item #50 0 0 0 0 0 DI] [l!] D oo ® oo Q D ~ [';JOI] oo D ~~===~ .. .._tttt!Tlm [';JOI] [J ll!l@ 0 00 0 (--~-~-;----~---r-~. I I i [2JO [';JOI] DlJ [';JOI] [l!J 'i 0 i @.@ • !□ ' I i ' l o,_ 0 000 0 C, [l [';] Q □□lllllloooc.o I •lilJ[l!J□OJ 0 0 0 0 ~ ff katz ~ JKA~~CHITECTURE w FINISH FLOOR 71112TO PARAPET 22 AUD,7O5,U00EE7,NG 5OO0220EE7,NG 5OO021OU7DOO5PA7,O16A47D4A47D28867T<P211A47D618T<P21217TO PLATE 211 TO PLATE 12 6TO JOIST 17 A78BA78B28686867T<P61 NOTES AND DETAILS APPL< TO ALL SECTIONS UNO2 FOR FINISH SCHEDULE SEE A61FINISH FLOOR GSNTO PARAPET 22 TO PARAPET 427 U0UL7,PU5PO6E5OO0B214.,7C+EN2567O5AGE20EE7,NG 5OO021A46D867888621211A78B221217T<P618A47D1A46D5A46D1TO PLATE 211 TO JOIST 422 8686586A46D2FINISH FLOOR TO PARAPET 217 6GSNTO PARAPET 22 0EE7,NG 5OO02167O5AGE2.,7C+EN2586788621211A78B2A46DA46D1T<P618A46D4TO PLATE 211 86865A46D2FINISH FLOOR TO PARAPET 217 67167O5AGE2%,NGO67O5AGE24+ALL26:O0EN 65E675OO021267O5AGE218618621211A48DA48D1A48DA48D4A48D2TO PLATE 211 TO JOIST 21 867A78B286586SIMFINISH FLOOR TO PARAPET 217 67111TO PLATE 211 8618621211A48DA48D1A48D2A48DA48D467O5AGE2%,NGO67O5AGE24+ALL26:O0EN 65E675OO0B21267O5AGEB21TO JOIST 21 A78B2867SIM865+)1+,8'/8+4°,+':9:2,)'5/2,+0)5'/48':@:94+)?*+)'8:./DHVFULSWLRQ DDWH PURMHFW NXPEHUDUDZQ B\CKHFNHG B\SKHHW TLWOHASSURYHG B\SKHHW NXPEHUZZZMHIINDW]DUFKLWHFWXUHFRPSCHEMATICDESIGN6/28/181 DESIGNDE9ELOPMENT5CONSTRUCTIONDOCUMENTS95CONSTRUCTIONDOCUMENTS8/2/181/22/1812/21/18BUILDING DEPTSUBMITTAL2/15/19BUILDING DEPTRESUBMITTAL4/17/19BID SET5/28/19REBID SET8/26/19'(/&(552%28/(9$5'_6$1',(*2&$_PURMHFW BUILDINGSECTIONS MULTIPURPOSEBLOCK1842A42MICKE< CAFAGNACOMMUNIT< CENTERCIT< OF PO:A<194 CLYLF CHQWHU DUPRZD\ CA 9264CMJKMM/AQCON675UC7,ON NO7E621CONCRETE FOOTING SEE STRUCTURAL DRA:INGS211 CONCRETE CURB SEE STRUCTURAL DRA:INGS217 CONCRETE SLAB ON GRADE SEE STRUCTURAL DRA:INGS6GLULAM BEAM SEE STRUCTURAL DRA:INGS618 ACOUSTIC SUSPENDED PANEL CEILING SEE A711621 G<PSUM BOARD CEILING SEE FINISH SCHEDULE AND D1/A7118P9C ROOFING86THERMAL BATT INSULATION865 SOUND BATT INSULATION867 CANOP< SEE B2/A78SCALE1/8 1 A42C1BUILDING SECTION MULTIPURPOSE BLOCKNO7E6SCALE1/8 1 A42B1BID ALT BUILDING SECTION MULTIPURPOSE BLOCKSCALE1/8 1 A42A1BUILDING SECTION MULTIPURPOSE BLOCKSCALE1/8 1 A42D1BUILDING SECTION MULTIPURPOSE BLOCKSCALE1/8 1 A42DBID ALT BUILDING SECTION MULTIPURPOSE BLOCK8 16 4 8 FOR CONSTRUCTION11/14/1912/11/1943 of 49October 20, 2020, Item #5' I ' l D CD--@ - -□-D I , , I I , , I l ~ -0 D D '----------{] 'ti D D H -0 -0 -0 -0 .. D .. -0 o-D -0 D r-------r-P-o ' I I I ' ' ' ! ! ! JKAj e f f k a t z ~ ARCHITECTURE w FINISH FLOOR TO PARAPET 217 6GJKPQT0EE7,NGCLA665OO018E9EN7COU57YA5DDANCE 67UD,O14T<P618T<P8A48D5867A78B2A49D1A49D2T<P217T<P21TO PLATE 211 TO PLATE 41 8TO JOIST 21 8686FINISH FLOOR TO PARAPET 217 62667O5AGE60EE7,NGCLA665OO080EE7,NGCLA665OO0967O5AGE12DANCE 67UD,O14A49DT<P618T<P8T<P421211211T<P21217TO PLATE 211 86865A78B28671 NOTES AND DETAILS APPL< TO ALL SECTIONS UNO2 FOR FINISH SCHEDULE SEE A61FINISH FLOOR TO PARAPET 217 6126E9EN7COU57YA5DPU%L,C :O5.6:O5. A5EA160EN 65E675OO01:O0EN 65E675OO02PLU0%,NGC+A6ET<P8T<P621211211T<P211A49D4A49D5T<P21217TO PLATE 211 TO JOIST 21 8686867A78B2FINISH FLOOR TO PARAPET 217 66TO JOIST 21 6658867A78B2FINISH FLOOR TO PARAPET 217 6P8665A78B2867+)1+,8'/8+4°,+':9:2,)'5/2,+0)5'/48':@:94+)?*+)'8:./DHVFULSWLRQ DDWH PURMHFW NXPEHUDUDZQ B\CKHFNHG B\SKHHW TLWOHASSURYHG B\SKHHW NXPEHUZZZMHIINDW]DUFKLWHFWXUHFRPSCHEMATICDESIGN6/28/181 DESIGNDE9ELOPMENT5CONSTRUCTIONDOCUMENTS95CONSTRUCTIONDOCUMENTS8/2/181/22/1812/21/18BUILDING DEPTSUBMITTAL2/15/19BUILDING DEPTRESUBMITTAL4/17/19BID SET5/28/19REBID SET8/26/19'(/&(552%28/(9$5'_6$1',(*2&$_PURMHFW BUILDINGSECTIONS CLASSROOMBLOCK1842A4MICKE< CAFAGNACOMMUNIT< CENTERCIT< OF PO:A<194 CLYLF CHQWHU DUPRZD\ CA 9264CMJKMM/AQSCALE1/8 1 A4A1BUILDING SECTION CLASSROOM BLOCKSCALE1/8 1 A4B1BUILDING SECTION CLASSROOM BLOCKNO7E6CON675UC7,ON NO7E621CONCRETE FOOTING SEE STRUCTURAL DRA:INGS211 CONCRETE CURB SEE STRUCTURAL DRA:INGS217 CONCRETE SLAB ON GRADE SEE STRUCTURAL DRA:INGS421 DOOR AND FRAME SEE DOOR SCHEDULE618 ACOUSTIC SUSPENDED PANEL CEILING SEE A711621 G<PSUM BOARD CEILING SEE FINISH SCHEDULE AND D1/A711665 STUCCO SOFFIT8P9C ROOFING86THERMAL BATT INSULATION865 SOUND BATT INSULATION867 CANOP< SEE B2/A78SCALE1/8 1 A4C1BUILDING SECTION CLASSROOM BLOCKSCALE1/8 1 A4D1BUILDING SECTION CLASSROOM BLOCKSCALE1/8 1 A4D2BUILDING SECTION CLASSROOM BLOCK8 16 4 8 FOR CONSTRUCTION11/14/1912/11/1944 of 49October 20, 2020, Item #5) D -0 co-t1i: = = =-= ~ cM------=-, 0 I -0 0 L I t __ -ou _ _) I,; -----0 D e f.l D i. 1---------D -----0 r D-;:;: 0 D µ laj 1---o 9 ~r'----0 . iJ -0 ~E I 1 j -0 Lw D-;:;: -.... r D H: ' ' ' ' ! ! ! ! D--'' I! D l CD{ ·t:·--------0 [}--Q i 0)-{2 ·1---------~ -0 l ~-~-f ,-....-----o [}--rd D i-,-i-----o CD-$ ;~=-=-~ 0 ... D D Jj ) 0----'------{] D i n 0 ~===~~ -0 -~ 1 j"hli I [\ -t I -i_J I ~!i i "' -l~ -o u ' D 0 I '~ ' ' ' ' (ll D---, ,~ 0 ! l ! I Cr (f i i ' l I I'~ ~ ~ I I I ' ' ' ~ ~ ~ ~ JKAj e f f k a t z ~ ARCHITECTURE w 52522T<P421T<P471T<P62T<P6852622A78BT<P611T<P618T<PPT5T<PPTT<PRB4T<PPT1698747874877169T<P47652522T<P42242142162284545454569869812NOTES AND DETAILS APPL< TO ALL ELE9ATIONS UNOFOR ADDITIONAL ACCESSIBILIT< REQUIREMENTS AND DETAILS SEE TSHEETSFOR ADDITIONAL FINISH INFORMATION SEE FINISH SCHEDULE+)1+,8'/8+4°,+':9:2,)'5/2,+0)5'/48':@:94+)?*+)'8:./DHVFULSWLRQ DDWH PURMHFW NXPEHUDUDZQ B\CKHFNHG B\SKHHW TLWOHASSURYHG B\SKHHW NXPEHUZZZMHIINDW]DUFKLWHFWXUHFRPSCHEMATICDESIGN6/28/181 DESIGNDE9ELOPMENT5CONSTRUCTIONDOCUMENTS95CONSTRUCTIONDOCUMENTS8/2/181/22/1812/21/18BUILDING DEPTSUBMITTAL2/15/19BUILDING DEPTRESUBMITTAL4/17/19BID SET5/28/19REBID SET8/26/19'(/&(552%28/(9$5'_6$1',(*2&$_PURMHFW INTERIORELE9ATIONS1842A54MICKE< CAFAGNACOMMUNIT< CENTERCIT< OF PO:A<194 CLYLF CHQWHU DUPRZD\ CA 9264CMJKMMCON675UC7,ON NO7E67ASSISTI9E LISTENING SIGN SEE D1/T674 MA;IMUM OCCUPANC< SEE D2/T68RECESSED FIRE E;TINGUISHER AND CABINET8SIGN TE;T E;IT 45ROOM SIGN421 DOOR AND FRAME SEE DOOR SCHEDULE422 DOOR SEE DOOR SCHEDULE471:INDO: SEE :INDO: SCHEDULE476 MOTORI=ED :INDO: SHADE SEE ELECTRICAL DRA:INGS AND DETAILC4/A75212  HIGH OPERABLE PARTITION ON PERMANENT TRACK :EIGHING18LB/LF522 OPERABLE :ALL CEILING TRACK611 CHAIR RAIL SEE FINISH SCHEDULE618 ACOUSTIC SUSPENDED PANEL CEILING SEE A71162G<PSUM BOARD SEE FINISH SCHEDULE FOR T<PE AND FINISH622 G<PSUM BOARD SOFFIT68RUBBER BASE SEE FINISH SCHEDULE69RE9EAL CHANNEL AT 6 ABO9E ACOUSTIC SUSPENDED PANEL SEEDETAIL C1/A79771:ALL MOUNTED PROJECTION SCREEN OFOI CONTRACTOR TOPRO9IDE BLOCKING AND COORDINATE ADDITIONAL REQUIREMENTS:ITH CIT< 9ENDOR5124,N7E5,O5 ELE9A7,ON NO7E6SCALE1/4 1 A54D1MULTIPURPOSE BLOCK MEETING ROOM INTERIOR ELE9ATIONS4 8 2 FOR CONSTRUCTION11/14/1912/11/1945 of 49October 20, 2020, Item #5'' '' ,~--------,,, "----------jl: ' ' It--------, : ' ' if----------ri: ' ' "----------jl: ' ' lt---------i,: ' ' if--------,,, 0---t--' ' ' :_-+--o 0 D-D-0---D-D-D-D-EB t--t--□ ~ / -□ Al -n u II -□ ~I 0-----0---nr-□ ~ J.----"-----0 ~--{] EB I EB II • I I --{] I ~ t-o II -• I I I -----0 ll • I I I I ---{] II ---{] EB I EB II 0 ~------,---(] JKAj e f f k a t z ~ ARCHITECTURE w 8421457445T<P75T<P76447 A78A182GDANCE 67UD,O14B1A566789KA1A564-AN98512T<P62T<P612T<P6779858 6 T<PT<P61242198567O5AGE1A1A56571271252571252554854812PU%L,C :O5.6:O5. A5EA16D1A5615454626812NOTES AND DETAILS APPL< TO ALL ELE9ATIONS UNOFOR ADDITIONAL ACCESSIBILIT< REQUIREMENTS AND DETAILS SEE TSHEETSFOR ADDITIONAL FINISH INFORMATION SEE FINISH SCHEDULEK5E675OO029D1A56111211494198IDCT<PEGHF¡ ;48 CLEAR;48 CLEAR18;6 CLEART4C2OQS421T<P62T<P615  T<PT<P615DIT<P612HFT<PESOQ94198T<P614CG;TOILET ACCESSOR< SEE TOILET ACCESSORIES SCHEDULE ON A6+)1+,8'/8+4°,+':9:2,)'5/2,+0)5'/48':@:94+)?*+)'8:./DHVFULSWLRQ DDWH PURMHFW NXPEHUDUDZQ B\CKHFNHG B\SKHHW TLWOHASSURYHG B\SKHHW NXPEHUZZZMHIINDW]DUFKLWHFWXUHFRPSCHEMATICDESIGN6/28/181 DESIGNDE9ELOPMENT5CONSTRUCTIONDOCUMENTS95CONSTRUCTIONDOCUMENTS8/2/181/22/1812/21/18BUILDING DEPTSUBMITTAL2/15/19BUILDING DEPTRESUBMITTAL4/17/19BID SET5/28/19REBID SET8/26/19'(/&(552%28/(9$5'_6$1',(*2&$_PURMHFW ENLARGEDPLANS INTERIORELE9ATIONS1842A56MICKE< CAFAGNACOMMUNIT< CENTERCIT< OF PO:A<194 CLYLF CHQWHU DUPRZD\ CA 9264CMJKMMCON675UC7,ON NO7E674 MA;IMUM OCCUPANC< SEE D2/T68SIGN TE;T E;IT 45ROOM SIGN421 DOOR AND FRAME SEE DOOR SCHEDULE54ROOF ACCESS LADDER525 2;6 DF :ITH COUNTERSUNK FASTENERS PRO9IDE BLOCKING548 2 2;12 BLOCKING SEE DETAIL A2/A7761CERAMIC TILE :AINSCOT :ITH INTEGRAL CO9E BASE SEE FINISHSCHEDULE612 CERAMIC TILE :ALLBASE SEE FINISH SCHEDULE614 FULL HEIGHT CERAMIC TILE :ITH INTEGRAL CO9E BASE SEE FINISHSCHEDULE615 BULLNOSE CERAMIC TILE TRIM SEE FINISH SCHEDULE62G<PSUM BOARD SEE FINISH SCHEDULE FOR T<PE AND FINISH68 RUBBER BASE SEE FINISH SCHEDULE677 FIBER REINFORCED PLASTIC SEE FINISH SCHEDULE712 24 DEEP SHEL9ING AT 84 AFF SEE DETAIL A2/A7775MIRROR764 DANCE BARRE PRO9IDE BLOCKING FOR BARRE BRACKETS941 HAND SINK SEE PLUMBING DRA:INGS98:ATER CLOSET SEE PLUMBING DRA:INGS984:ATER HEATER SEE PLUMBING DRA:INGS985 MOP SINK SEE PLUMBING DRA:INGS6789SCALE1/4 1 A56B1CLASSROOM BLOCK DANCE STUDIO ENLARGED PLAN AND INTERIOR ELE9ATIONSSCALE1/4 1 A56A1CLASSROOM BLOCK JANITOR ENLARGED PLAN AND INTERIOR ELE9ATION124SCALE1/4 1 A56ACLASSROOM BLOCK STORAGE ENLARGED PLAN AND INTERIOR ELE9ATION T<PICAL5SCALE1/4 1 A56D1CLASSROOM BLOCK PUBLIC :ORKS ENLARGED PLAN AND INTERIOR ELE9ATION1,N7E5,O5 ELE9A7,ON NO7E6SCALE1/4 1 A56DCLASSROOM BLOCK RESTROOM1112114LEGEND4 8 2 FOR CONSTRUCTION11/14/1912/11/1946 of 49October 20, 2020, Item #5D 1J) 1 I 0 er---~ ~ D 0--0----1 ITT I I I I 0 n----= ) 0---,__ 1-----D -:::-· "" .~ . ' I" ¾-~ ' I" ~ " II I , 0 ' 0--~ ~ "-~ ~ " ~ I~~ □ 7, ] I ◊□ I 0 0 n----D 0 0 ~" I • 0 0 l l ~: 0 0--1,,---------t ~I I 0 ED ~I OD 0 o-RrR 0--~ JKAj e f f k a t z ~ ARCHITECTURE w October 20, 2020, Item #5ATTACHMENT 2 * * Proposal** Project Number: 2009CPCA r PROJECT INFO: Mickey Cafagna Community Center EXPERIENCE THE DIFFERENCE 2425 Auto Park Way Escondido, CA 92029 \.. 760-737-3900 Fax 760-737-3929 r \.. City of Poway Attn: Accounts Payable PO Box 789 Poway, CA 9207 4 Tel: 858-668-4624 r BILL TO: \.. SHIP TO: City of Poway Lawrence Brillon 13325 Civic Center Dr Poway, CA 92064 Tel: 858-668-4624 Mfr-Part No. Qty Description EQUIPMENT & MATERIALS: Assisted Listening Devices LISTECCOR-LW-200 1 Listen EVERYWHERE 8 Channel Server P-08-01 LISTECCOR-LT-800-3 Stationary RF Transmitter (72 MHz) 072-01 LISTECCOR-LA-326 2 Universal Rack Mounting Kit LISTECCOR-LA-122 3 Universal Antenna Kit (72 and 216 MHz) LISTECCOR-LR-3200 13 Basic DSP RF Receiver (72 MHz) -072 LISTECCOR-LA-430 4 Intelligent Ear Phone/Neck Loop Lanyard LISTECCOR-LA-402 13 Universal Stereo Headphones LISTECCOR-LA-381-1 Intelligent 12-Unit Charging Tray 01 Auditorium Meeting Rooms 201 & 202 Epson - L 1495UNL 1 WUXGA 9000 lumens Projector (Black) Epson -ELPLU03 1 Short Throw Projector Lens LEGRANAV-VCMU 1 VCMU INCL CUSTOM HBU BLK 1 Custom 220" Diag. Projection Screen LEGRANAV-38797L 1 CONTOUR TNSD 220D HD.6 Extron-60-1421-53 2 Long Distance DTP Transmitter for HDMI -Extron-60-1331-13 3 Long Distance HDMI Twisted Pair Receiver -330 Extron-60-1331-12 2 Long Distance HDMI Twisted Pair Transmitter -330 Extron-60-1531-52 1 Long Distance DTP Receiver for HDMI -QSCAUDPRO-NV-32 2 4K60 4:4:4 Network Video Endpoint for the Q-SYS -H SHUBRO-ULXD4Q=-1 ULXD4Q QUAD WIRELESS RECEIVER J50A SHUBRO-ULXD1 =-JS 4 Digital Wireless Bodypack Transmitter with 0A SHUBRO-WL 185 4 Microflex Cardioid Lavalier Microphone SHUBRO-ULXD2/SM 4 Handheld Transmitter with SM58 Microphone 58=-JS0A SHUBRO-SB900A 8 Shure Lithium-Ion Rechargeable Battery SHUBRO-SBC200-U 1 Dual Docking Charger with PS45US Power Supply s 47 of 49 10/7/2020 Sound Image Project: 2009CPCA 10/7/2020 Page 1 of 3 October 20, 2020, Item #5Mfr-Part No. Qty Description SHUBRO-SBC200 3 Dual Docking Charger, Power Supply NOT Included RFVENINC-COMBIN 1 COMBINE4 Antenna Combiner/Zone Controller E4 SHUBRO-UA834WB 0 In-line antenna amplifier for remote mounting. SHUBRO-UA221 0 Passive Antenna Splitter/Combiner Kit. Includes RFVENINC-DFINW 3 Diversity Fin Antenna Install White SHUBRO-UA8-578-6 0 1/2 Wave Omnidirectional Antenna for UR4S+, UR4D+ 38 QSCAUDPRO-CX-Q 1 8-Channel 1 000W/CH Q-SYS Network Amplifier, Lo-Z, 8K8 QSCAUDPRO-AD-C6 20 6.5 Two-way ceiling speaker, 70/1 00V transformer T-BK QSCAUDPRO-CORE 1 Unified Core with 24 local audio 1/0 channels, 110F QSCAUDPRO-SL-QS 1 Q-SYS Core 110 Scripting Engine Software License, E-110-P QSCAUDPRO-SL-QU 1 Q-SYS Core 110 UCI Deployment Software License, D-110-P QSCAUDPRO-TSC-8 1 Q-SYS 8.0 PoE Touch Screen Controller for In-Wall 0W-G2-BK Wolfvision -Cynap 1 Wireless Media Player Pure Pro QSCAUDPRO-UNDX 1 4x2 Channel 2 Gang US Dante/AES67 Wall Plate 2 210+ LEGRANAV-DWR-24-1 24SP/22D WALLRACK W/PLEXI 22PD Multipurpose Room 8214 Epson - L 1495UNL 2 WUXGA 9000 lumens Projector (Black) Epson -ELPLU04 2 Short Throw Projector Lens LEGRANAV-VCMU 2 VCMU INCL CUSTOM HBU BLK Extron-60-1421-53 2 Long Distance DTP Transmitter for HDMI -Extron-60-1331-13 4 Long Distance HDMI Twisted Pair Receiver - 330 Extron-60-1331-12 2 Long Distance HDMI Twisted Pair Transmitter - 330 QSCAUDPRO-NV-32 2 4K60 4:4:4 Network Video Endpoint for the Q-SYS -H QSCAUDPRO-CX-Q 1 8-Channel 1 000W/CH Q-SYS Network Amplifier, Lo-Z, 8K8 QSCAUDPRO-AD-C6 16 6.5 Two-way ceiling speaker, 70/1 00V transformer T-BK Dance Studio Room 314 QSCAUDPRO-AD-C6 8 6.5 Two-way ceiling speaker, 70/1 00V transformer T-WH QSCAUDPRO-CX-Q 1 8-Channel 500W/CH Q-SYS Network Amplifier, Lo-Z, 4K8 QSCAUDPRO-UND6I 1 4x2 Channel 2 Gang US, Dante/AES67 Wall Plate O-BT QSCAUDPRO-UNDX 1 4x2 Channel 2 Gang US Dante/AES67 Wall Plate 2 210+ LEGRANAV-DLBX 1 DVR LOCK BOX QSCAUDPRO-KS 112 2 2000W active, Compact subwoofer; 12-inch woofer; Extron-22-235-03 4 Shielded Digital Twisted Pair Cable for XTP & DTP 48 of 49 Sound Image Project: 2009CPCA Page 2 of 3 10/7/2020 October 20, 2020, Item #5Mfr-Part No. ANIXTER-2413-1000 ANIXTER-9116-1000 ANIXTER-9258-1000 ANIXTER-6100UE-10 00 SOUNDIMG-MATERI ALS & SUPPLIES Qty Description 2 Cable, CAT6+ (350 MHz), 4-Pair, U/UTP-Unshielded, Plenum-CMP 1 Cable, Series 6, 18 AWG solid 1 Cable, RG-8X type, 16 AWG stranded (19x29) 2 Cable, Plenum-CL2P 2-14 AWG stranded 1 Materials & Supplies Equipment & Material Subtotal Project Allowance for Design Variance Labor Subtotal Extras (Lift & Tool Rentals) Subtotal This * * Proposal * * is Valid for 30 Days. Freight: 1,182.33 Approved By: _________________ Date: ___ _ 49 of 49 10/7/2020 Sound Image Project: 2009CPCA Shipping & Handling: $ CA Sales Tax $ 105,142.11 2,000.00 51,200.00 945.05 1,182.33 8,303.51 Project Total: $ 168,773.00 Page 3 of 3