Loading...
Res P-97-61RESOLUTION NO. P-g7-61 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF POWAY, CALIFORNIA APPROVING MINOR DEVELOPMENT REVIEW 97-63 (HILLSlDE/RIDGELINE) ASSESSOR'S PARCEL NUMBERS 321-110-45 WHEREAS, Minor Development Review 97-63 (Hillside/Ridgeline), submitted by Andrew Pavelchek/Sally Wixted, Applicants, requests approval 1 : a 4,644 sq. ft. house, 1,328 sq. ft. garage plus guest house of 1,345 sq. ft. with a 504 sq. ft. garage on a 14.9 acre site, at 15545 Westview Rd., west of Mina de Oro Rd. (portion of road off Highway 67) within the RR-A zone. WHEREAS, on November 4, 1997, the City Council held a hearing to solicit from the public, both pro and con, relative to this application. NOW, THEREFORE, the City Council does hereby follows: The previously issued Negative Declaration with Mitigation Measures (indicating no significant adverse Iai impacts anticipated due to the addition of special requirements to the project) for Tentative Parcel Map 91-11 adequately addresses the potential impacts of the proposed development. 1 2: Fin. The approved project is consistent with the general plan in that it proposes the construction of a single family residence with garage on property that is designated for residential use. That the approved development will not have an ad :hetic, health, safety or architecturally related impact upon adjoining properties, in that the residence is compatible with existing homes in the area and the grading has been designed to appear natural and ' ' ale impacts. That the approved development is in compliance with the Zoning and Grading Ordinance, in that it complies with the property development standards of the RR-A zone. That the approved development encourages the orderly and h appearance of and property within the City, in that the surrounding properties consist of large rural residential lots with widely spaced hillside h Resolution No. P- 97-61 Page 2 ;ision: The City Council hereby approves Minor Development Review 97-63 (Hillside/Ridgeline) subject to the following conditions: COMPLIANCE WITH THE FOLLOWING CONDITIONS IS REQUIRED. COMPLIANCE SHALL BE APPROVED BY THE DEPARTMENT OF PLANNING SERVICES. 1. Within 30 days of approval, the applicant shall submit in writing that all conditions of approval have been read and understood. The use conditionally granted by this permit shall not be conducted in such a to interfere with th 3ie use and enjoyment of the surrounding industrial and open space uses. This conditional use permit shall be subject to annual review by the Director of Planning Services for compliance with the conditions of approval and to address concerns that may have occurred during the past year. if the permit is not in compliance with the conditions of approval, or the Planning Services Department h :1 complaints, the required annual review shall be set for a public hearing before the City Council, to consider modificat' ;ion of the use permit. SITE DEVELOPMENT 1. Site shall be developed in accordance with the approved grading plans on file in the Planning Services Department and the condil' :1 herein. Revised site plans and building elevat' ~orating all conditions of approval shall be submitted to the Planning Services Department pdorl =grading and building permits. The guest house square footage shall be reduced by at least '184 square feet to comply with the 25% ratio for the main h the guest house square footage. The kitchen area shown on the guest house floor plan shall be modified to some other use. Approval of this request shall not 31lance with the Zoning Ord :1 all other applicable City Ordinances in effect at the time of grading and building permit issuance. The applicant shall comply with the latest adopted Uniform Building Code, Uniform Mechanical Code, Uniform Plumbing Code, National Electric Code, Uniform Fire Code, and all other applicable codes and ord fect at the time of building permit issuance. Resolution No. P- 97-61 Page 3 The applicant shall pay all applicable fees, including school fees at a rate of $1.84 per square foot of assessable space (living area) prior to building permit issuance. The developer shall pay an Affordable Housing In-Lieu Fee in the amount of $4,500 to the Planning Services Department prior to building permit issuance. A covenant shall be recorded that the guest house shall not be rented or leased, the breezeway shall not be enclosed and a kitchen shall not be installed. A conditional use permit would be required for the guest house to qualify as a second dwelling unit. 8. L within th 10. 11. plumbing fixtures and Iow water usage irrigation, shall be installed ':lence, the guest house and its surrounding landscaping. Future grading of the hillside portions of the subject lot shall be prohibited unless approved by the City Council. All pertinent conditions of Resolution No. P-92-63 for Tentative Parcel Map 91-11 (Parcel Map 17458) shall apply, e.g. limiting grading to three acres plus a reasonable length driveway. The grading on the site shall not exceed three acres plus a reasonable driveway access. 12. This approval shall I~ II and void if building p : issued for this project within two years from the date of project approval. COMPLIANCE WITH THE FOLLOWING CONDITIONS IS REQUIRED. COMPLIANCE SHALL BE APPROVED BY THE DEPARTMENT OF ENGINEERING SERVICES. A grading plan for the development of the property shall be submitted to the City's Engineering Services Department for review and approval prior to issuance of a grading permit and start of grading operation. Rough grading of the site must be completed and shall meet the City's Engineering S 3ector's approval prior 1' : a building permit. The grading plan shall be drawn 1 : 1" = 20' or larger. A right-of-way permit shall be obtained from the City's Engineering Services Department for any work to be done within the public street right-of-way or any City- held easement. Said work shall include, but is not limited to, ~ ddveway approach, sewer lateral installation, water service line installation, and street construction. Resolution No. P- 97-61 Page 4 Leach field layout or seepage pit layout for the residence sewage disposal system shall be submitted to the City's Engineering Services Department for review and approval by the City Engineer prior to obtaining a septic system installation permit from the County of San Diego Department of Health. If a septic system installation permit had been obtained without a City approved layout, one shall be submitted prior to installation of leach lines. The following fees shall be paid or a security bond posted prior to issuance of a building permit. If a security bond is posted, payment of the fees shall be made prior ~ a Certificate of Occupancy. Once payment is received in full said security bond could be released to the applicant. Traffic Mitigation = $990.00 Park = $2,650.00 COMPLIANCE WITH THE FOLLOWING CONDITIONS IS REQUIRED. COMPLIANCE SHALL BE APPROVED BY THE DEPARTMENT OF SAFETY SERVICES. Roof covering shall meet Class A fire retardant testing as specified in the Uniform Building Standards No. 32-7 for fire retardant roof covering per City of Poway Ordinance #64. Approved numbers or addresses shall be placed on the building in such a position as to be plainly visible and legible from the street fronting the property. Said numbers shall contrast with their background. Address shall be required at private driveway entrances. Each chimney used ' arrester. any fireplace shall :1 with a spark Every building hereafl :ted shall be accessible to fire department apparatus by way of access roadways with all-weather driving surface of not less than 20 feet of unobstructed width, with adequate roadway turning radius capable of supporting the imposed loads of fire apparatus and having a minimum of 13'6" of vertical The road surface type shall be approved by the City Engineer, pursuant to the City of Poway Municipal Code. Dead end access roadways in excess of 150 feet long shall be provided with approved provisions for the turning around of Fire Department apparatus. The · ' ':lth required is 20 feet*, with a 70' d' Je-sac or hammerhead. [*Curves and topographical conditions could alter the req ' for turnarounds and the width of ~/s.] Resolution No. P- 97-61 Page 5 The access roadway shall be extended to within 150' of all portions of the exterior walls of the first story of any building. Where ti: Jway cannot be provided, approved fire protection system(s) shall be provided as required and approved by the Chief. This dwelling is being built on a parcel size of 14.9 acres and is beyond 500 feet from the nearest fire hydrant. The dwelling will have to have standby water for fireflghting and a residential sprinkler system. Contact the Fire Prevention Bureau for details. 8. A residential fire sprinkler system will be required. Plans shall be submitted to the Fire Prevention Bureau for approval prior to installation. 9. Both main house and guest house shall be provided with a residential fire sprinkler system. 10. Driveway shall be an "all weather" surface as per City of Poway Engineering specifications. 11. A 4" Sch. 80 or galvanized pipe shall run to a point in the driveway from the water tank with a 2 ¼" national std. thread Contact the Fire Department for exact location. 12. Water tank shall have a 10,000 gallon capacity. APPROVED and ADOPTED by the City Council of the City of Poway, State of California, this 4th day of November 1997. ATTEST: Don Higginson, Mayor Marjorie K. Wahlsten, City Clerk Resolution No. P- 97-61 Page 6 STATE OF CALIFORNIA ) )ss. COUNTY OF SAN DIEGO) I, Marjorie K. Wahlsten, City Clerk of the City of Poway, do hereby certify, under the penalty of perjury, that the foregoing Resolution, No. P-97-61 . was duly adopted by the City Council at a meeting of said City Council held on the 4th day of November 1997, and that it was so adopted by the following vote: AYES: CAFAGNA, NOES: NONE ABSTAIN: NONE ABSENT: GOLDBY EMERY, REXFORD, HIGGINSON Marjone K. Wahlsten, City Clerk City of P,.O~Nay